Bosch · Thermocouple with amplifier (0-5 V)
Bosch TCP-N amplified EGT thermocouple probe
The Bosch TCP-N is a flexible type N (NiCrSi-NiSi) thermocouple probe for exhaust gas temperature with the amplifier built in: it runs on 12 V and outputs 0.5-4.5 V for -40 to 1,100 °C, so it wires straight to an analog input. Response time is 20 s for the TCP-N and 33 s for the TCP-NF.1
Key specifications
Measures: Exhaust gas temperature (-40 to 1,100 °C). Output: Thermocouple with amplifier (0-5 V).
Pinout and connector
No pinout is shown: the maker or OEM does not publish one in a document we could cite. Identify pins with a meter before wiring.
Connector: 1-J0973-70 (TCP-N); D 261 205 276 (TCP-NF)1 Connector library
Terminals and seals: Not listed: the Bosch data sheet gives the mating housing only, not contact or seal part numbers.
Transfer function and calibration data
Show the 13 data points
| Temperature (°C) | Output (mV) |
|---|---|
| -40 | 372 |
| 0 | 485 |
| 100 | 790 |
| 200 | 1,135 |
| 300 | 1,513 |
| 400 | 1,912 |
| 500 | 2,327 |
| 600 | 2,752 |
| 700 | 3,183 |
| 800 | 3,615 |
| 900 | 4,046 |
| 1,000 | 4,473 |
| 1,100 | 4,845 |
How it's calibrated
ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.
Transfer function
- 0.37–4.84 V → -40–1,100 °C1
Worked conversion
- At 2.61 V the output corresponds to 567 °C.1Calculated from the maker's data
Output vs temperature: output voltage to temperature (9 rows)Calculated from the maker's data
| Output (V) | Temperature (°C) |
|---|---|
| 0.5 | 4.9 |
| 1 | 160.9 |
| 1.5 | 296.6 |
| 2 | 421.2 |
| 2.5 | 540.7 |
| 3 | 657.5 |
| 3.5 | 773.4 |
| 4 | 889.3 |
| 4.5 | 1007.3 |
Interpolated between the maker's published points; nominal values with no tolerance band.
Native support across ECUs
| ECU platform | Status | How to set it up | Source |
|---|---|---|---|
| GAINS ECU2Concept | Configurable (generic input) | Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware. | Medium2 |
| Haltech (Elite / Nexus) | Configurable (generic input) | Analog voltage input (AVI). Haltech's wiring diagram says inputs are user definable in software; enter the maker's transfer function. | 45 |
| Link (G4X) | Configurable (generic input) | Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered. | Medium6 |
| MoTeC (M1) | Configurable (generic input) | Analogue voltage input (17 on the M150). MoTeC's sensor pages show a manual-calibration option in M1 Tune. | Medium78 |
| ECUMaster (EMU Black) | Configurable (generic input) | One of 9 analog 0-5 V inputs. ECUMaster lists user-defined sensor characteristics for some functions. | Medium9 |
| AEM (Infinity) | Configurable (generic input) | Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered. | Medium10 |
| MaxxECU | Configurable (generic input) | Extra 0-5 V input (6 on the RACE). The public page does not describe calibration entry. | Medium11 |
| Holley (Terminator X / EFI) | Configurable (generic input) | '5' analog input, set up as a custom sensor in Holley's software (per the wiring manual). | 12 |
Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.
Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.
CAD and drawings
- Data sheetThermocouple Probe TCP-N / TCP-NF data sheet (PDF)1Download from Bosch MotorsportNo login at last check; the maker may change this
We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.
Wiring and installation
Signal to an analog input with no pull-up; 12 V supply from a fused switched feed. The table is not quite linear, so enter it as a table rather than a straight line.Medium1
Failure modes and checks
Frequently asked
Related
Use it with GAINS
Bosch TCP-N amplified EGT thermocouple probe on GAINS hardware
GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.23
Concept Pre-release hardware. Pin assignments come from the current design documents and may change.
Sources
12 sources
- Thermocouple Probe TCP-N / TCP-NF data sheet · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-10-27
- internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
- internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
- Nexus R3 wiring diagram (HT-193000_WD) · Haltech · vendor-doc · retrieved 2026-10-27
- Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-10-27
- G4X FuryX product page · Link Engine Management · vendor-doc · retrieved 2026-10-27
- M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
- TMAP Sensor product page · MoTeC · vendor-doc · retrieved 2026-10-27
- EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-10-27
- Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
- MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-10-27
- HP / Dominator EFI wiring manual 199R10555 · Holley · vendor-doc · retrieved 2026-10-27
Not yet indexed: fewer than 3 FAQs.