Exhaust gas temperature (EGT) sensor

EGT sensorEGT probepyrometerexhaust thermocoupleK-type thermocouple

An exhaust gas temperature (EGT) sensor is a probe, usually a type K thermocouple, that measures exhaust gas temperature in a runner, collector or turbine inlet. Tuners use it to compare cylinders, protect turbines and catalysts, and see how mixture and ignition timing change the heat leaving the engine.342

How it works

A thermocouple is two dissimilar metals joined at the hot end.

A temperature difference between that junction and the reference junction at the instrument produces a small voltage. Type K, chromel and alumel, is the usual exhaust choice because it covers -270 to 1,370 °C (-454 to 2,498 °F).35

The signal is small

Type K produces about 39.5 µV per °C near 0 °C and about 41 mV at 1,000 °C (1,832 °F) against a 0 °C reference. An amplifier must boost it and add cold-junction compensation, which measures the terminal temperature and adds back the matching voltage.563

Probe construction sets speed

Exposed and grounded junctions respond fastest; ungrounded junctions, insulated from the sheath, respond slowest but avoid ground loops. Sheathed probes are slow by engine standards: Bosch quotes 20 s for its TCP-N. EGT shows trends over seconds, not single combustion events.57

Some probes include the amplifier. Bosch's TCP-N uses a type N element, runs from 12 V and outputs 0.5 to 4.5 V over -40 to 1,100 °C (-40 to 2,012 °F), so it connects to an ordinary analog input.7

Placement sets the number. A probe in a primary runner near the port sees hotter, more pulsating gas than one at the collector or turbine inlet, because gas cools and mixes as it travels. Keep insertion depth and distance from the port the same on every cylinder.Medium42

Typical values

Type K sensitivityAbout 39.5 µV/°C at 0 °CSourced5
Type K output at 1,000 °C (1,832 °F)About 41 mV against a 0 °C referenceSourced6
Type K range-270 to 1,370°C-454 to 2,498 °FSourced5
Amplified probe (Bosch TCP-N)
  • 0.5-4.5 V for -40 to 1,100 °C
  • 12 V supply
  • Type N
Sourced7
Probe response (Bosch TCP-N / TCP-NF)20s / 33 sSourced7
Gasoline EGT at high loadCan exceed about 1,000 °C at the upper end1,830 °FHoneywell patent background; diesel about 100 °C at idle to 500 °C at high load. Actual values depend on probe position and engine.Sourced · medium8

How an ECU uses it

An ECU reads EGT on a dedicated thermocouple input, or through an external amplifier on a 0-5 V analog input.

Because probes respond in seconds, EGT suits protection and trend logging rather than cycle-by-cycle control.57

Protection strategies compare EGT with a limit taken from the turbine, manifold or catalyst maker's data. Above the limit for a set time, the ECU can add fuel, reduce boost or reduce load. Many OEM systems model exhaust temperature instead of measuring it and enrich at high load to protect components.Medium21

Per-cylinder EGT can guide cylinder trims. A cylinder running hotter or cooler than its neighbors points to a fuel, airflow or ignition difference. Trim the cause, then confirm the change with lambda and knock data.Medium24

How to test it

5 checks, in order.

  1. Check the reading cold. With the engine off and cold, EGT should read close to ambient. A reading stuck at a fixed value, at the amplifier's own temperature or at full scale points to an open probe or a broken extension wire.Medium35
  2. Check probe continuity. Unplugged, a bare thermocouple should show continuity end to end. An open circuit means a burned-through junction or broken lead; many amplifiers detect this with a small burn-out current and flag a fault.Medium5
  3. Check the wire type. Run thermocouple extension wire of the same type all the way to the amplifier. A copper section or a wrong-type connector creates extra junctions that offset the reading by tens of degrees.Medium3
  4. Check for ground loops on grounded or exposed probes. If the reading shifts when the fans or ignition load change, the probe's contact with the exhaust is adding a ground offset. An ungrounded probe or an isolated input cures it.Medium5
  5. Safety
    exhaust parts reach several hundred degrees within minutes. Fit or remove probes only on a cold engine, and seal the boss so an exhaust leak cannot draw in air and upset a downstream wideband sensor.Medium1

Symptoms and causes

EGT reads ambient or does not rise when the engine is hot

Likely causes Open junction, broken extension wire or unplugged probe

Check Check continuity; an open probe often reads the amplifier's own temperature or a rail.

Medium35

Reading offset by tens of degrees

Likely causes Copper or wrong-type wire or connector, or poor cold-junction compensation

Check Compare with ambient on a cold engine; fix the wire type before recalibrating.

Medium35

One cylinder much hotter than the rest

Likely causes Lean cylinder, weak injector, late ignition on that cylinder, or a deeper probe

Check Swap probes or injectors between cylinders; a fault that follows the part is the part.

Medium24

EGT climbs while lambda holds steady

Likely causes Ignition retard from knock control, a boost increase or an exhaust restriction

Check Log timing, knock retard and boost with EGT; timing pulled at the same moment explains the rise.

Medium21

Noisy or jumpy EGT

Likely causes Ground loop on a grounded probe, or ignition noise on long unshielded runs

Check See whether noise tracks ignition or fan load; use an ungrounded probe or twisted thermocouple wire.

Medium5

In tuning

Exhaust temperature responds to mixture, ignition timing and load.

Late combustion from retarded timing and very lean or very rich mixtures can all raise or lower EGT in ways that are not obvious, so EGT is best read alongside lambda, timing and knock rather than as a tuning target on its own.Medium21

Per-cylinder probes help balance cylinders on engines with uneven runner flow or injector variation, and pre-turbine probes protect turbine wheels. Turbine and catalyst temperature limits come from the component maker, not from a generic number.Medium24

Use EGT as a guard, not a target. Extra fuel lowers EGT partly because unburned fuel absorbs heat, so chasing a lower number with fuel alone wastes fuel and can wash cylinder walls. Fix the cause, such as late combustion, first.Medium21

Formula and worked example

Common mistakes

Mistake Comparing EGT numbers with another car or a chart online.

Do instead Compare only against your own baseline with the same probe, depth and location.Medium4

Mistake Wiring a bare thermocouple straight into a 0-5 V input.

Do instead Use a thermocouple amplifier with cold-junction compensation, or an amplified probe with a 0.5-4.5 V output.57

Mistake Expecting EGT to catch knock or a lean spike instantly.

Do instead Probes take seconds to respond; rely on knock and wideband lambda for fast protection and on EGT for heat trends.Medium72

Mistake Fitting per-cylinder probes at different depths or distances from the ports.

Do instead Match depth and distance on every runner so the readings compare.Medium4

Myths vs facts

Myth Lower EGT always means a safer tune.

Fact EGT is affected by combustion phasing. Advancing timing usually lowers EGT but raises knock risk, and some rich mixtures lower EGT at a cost in power and oil dilution. EGT must be read with lambda and knock data.Medium21

Myth Running leaner always makes EGT hotter.

Fact EGT tends to peak near stoichiometric and falls as the mixture goes richer or much leaner. A very lean engine can show lower EGT while still risking damage, and late timing raises EGT whatever the mixture.Low2

Myth A thermocouple can be wired straight to an ECU analog input.

Fact The signal is millivolts and depends on the reference junction temperature. It needs a thermocouple amplifier with cold-junction compensation, which most ECUs provide only on dedicated inputs.35

Frequently asked

What does an EGT sensor measure?

It measures the temperature of the exhaust gas where the probe sits, usually in a runner, collector or before the turbine. That temperature reflects how much combustion heat leaves the cylinder, so it changes with mixture, ignition timing, load and engine speed.42

What is a normal exhaust gas temperature?

There is no single normal value. EGT depends on load, rpm, probe position and engine type: gasoline engines run far hotter at full load than at idle, and turbo engines see their highest readings at the turbine inlet under sustained boost. Set limits from component makers' ratings and your own baseline logs.Medium24

Where should an EGT probe be installed?

For cylinder comparison, in each primary runner at the same distance from the port. For turbine protection, in the manifold or collector just before the turbine inlet. Keep insertion depth consistent and avoid placing it where one cylinder's pulse dominates a shared reading.Medium42

What causes high exhaust gas temperature?

Late combustion is the usual cause: ignition timing retarded by the calibration or by knock control, slow-burning mixtures, or more boost than the fuel tolerates. Exhaust restriction, a lean cylinder and long periods at full load also raise EGT. Log timing, knock, lambda and boost together to see which changed.Medium21

Why do I need a thermocouple amplifier?

The thermocouple produces only tens of millivolts, and its voltage depends on the temperature difference between hot and reference junctions. An amplifier boosts the signal and compensates for the reference junction temperature so the ECU or logger sees a stable, correct reading.35

Wiring, pinouts and parts

Sources

Numbered as cited above. Hover or tap a citation chip to preview it.

  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-10-27
  2. Internal Combustion Engine Fundamentals, 2nd edition (2018) · McGraw-Hill (John B. Heywood) · book · retrieved 2026-10-27
  3. Thermocouple · Wikipedia · reference · retrieved 2026-10-27
  4. Exhaust gas temperature gauge · Wikipedia · reference · retrieved 2026-10-27
  5. A Basic Guide to Thermocouple Measurements (SBAA274A) · Texas Instruments · vendor-doc · retrieved 2026-10-27
  6. NIST ITS-90 Thermocouple Database (SRD 60), type K reference table · National Institute of Standards and Technology · standard · retrieved 2026-10-27
  7. Thermocouple Probe TCP-N / TCP-NF data sheet · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
  8. US 9,702,266 B2: Turbocharger turbine housing · Honeywell International Inc. (Google Patents) · oem · retrieved 2026-10-27