Sensor type · Thermocouple (mV) · Thermocouple with amplifier (0-5 V)

EGT sensor (thermocouple + amplifier)

exhaust gas temperature sensorEGT probepyrometerthermocouple

An EGT sensor is a thermocouple: two dissimilar metals that produce a few millivolts proportional to temperature difference. ECU analog inputs cannot read that directly, so the probe needs an amplifier with cold-junction compensation that outputs 0-5 V. Bosch's TCP-N probe builds the amplifier in and outputs 0.5-4.5 V for -40 to 1,100 °C.15

Parts in the library

Support across ECUs

Across the 1 part in this hub (0 with a maker-verified pinout). Open a part for the setup notes and sources.

GAINS ECU21 configurable (generic input)
Haltech (Elite / Nexus)1 configurable (generic input)
Link (G4X)1 configurable (generic input)
MoTeC (M1)1 configurable (generic input)
ECUMaster (EMU Black)1 configurable (generic input)
AEM (Infinity)1 configurable (generic input)
MaxxECU1 configurable (generic input)
Holley (Terminator X / EFI)1 configurable (generic input)

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

How it works

A type K thermocouple produces about 41 mV at 1,000 °C relative to a 0 °C reference junction, per the NIST ITS-90 tables.4

Because the output depends on the temperature difference, the amplifier must measure its own terminal temperature (cold-junction compensation) and add it back.Medium5

Probe response is slow by engine standards: Bosch quotes 20 s for the TCP-N and 33 s for the TCP-NF.1

Types and variants

Bare thermocouple (type K)Thermocouple (mV)

Millivolt output; needs an amplifier with cold-junction compensation and thermocouple wire to the amplifier.45

Amplified probeThermocouple with amplifier (0-5 V)

Bosch TCP-N: type N element, 12 V supply, 0.5-4.5 V output, M12x1 thread.1

Wiring

Use thermocouple extension wire of the same type from the probe to the amplifier. Ordinary copper wire adds unintended junctions and errors.Medium5

Once amplified, the 0-5 V signal wires like any analog sensor: signal, sensor ground and supply as the amplifier requires.Medium1

Connector and wiring library

Common faults and checks

EGT reads room temperature with the engine hot

Likely cause Open thermocouple junction or broken extension wire

Check Measure continuity of the probe; an open probe reads the amplifier's own temperature or rails.Medium5

EGT reading offset by tens of degrees

Likely cause Copper wire or wrong-type connector between probe and amplifier

Check Use same-type thermocouple wire and connectors to the amplifier.Medium5

Frequently asked

Can an ECU read a thermocouple directly?

Not on a normal 0-5 V analog input. A thermocouple produces millivolts (about 41 mV at 1,000 °C for type K) and needs cold-junction compensation, so it goes through an amplifier first.45

Type K or type N for EGT?

Both are used. Type K is the common choice; Bosch builds its TCP-N probe on a type N (NiCrSi-NiSi) element rated to 1,100 °C. Match the amplifier to the type.Medium14

How fast does an EGT probe respond?

Slowly compared with other engine sensors. Bosch quotes 20 s for the TCP-N and 33 s for the TCP-NF, so EGT shows trends rather than single-cycle events.1

Related

Use it with GAINS

EGT sensor on GAINS hardware

ECU2AVI (amplified 0-5 V EGT)

Pins
On the ECU2 pin map
Pull-up
Off
Shielding
Not needed

Only through an external amplifier or an amplified probe; the ECU2 has no thermocouple input.Medium2

Neither the ECU2 nor the PDM2 lists a thermocouple input in its specification, so EGT needs an amplifier.23

GAINS hardware is pre-release concept design. Pin numbers come from the ECU2 v0.3 pin map and the PDM2 specification and can change before release; none of it has been tested on a vehicle yet.23

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

  1. Thermocouple Probe TCP-N / TCP-NF data sheet · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-10-27
  2. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  3. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  4. NIST ITS-90 Thermocouple Database (SRD 60), type K reference table · National Institute of Standards and Technology · standard · retrieved 2026-10-27
  5. Thermocouple · Wikipedia · reference · retrieved 2026-10-27

Not yet indexed: fewer than 4 FAQs.