Automotive wire gauge calculator

Pick wire size by voltage drop: enter the load current, run length and your allowed drop (3% is a common limit for critical loads such as fuel pumps) to see the drop for every AWG and metric size.

A
V
%
°F

Hot engine bays raise copper resistance about 0.4% per °C.

Result

Smallest AWG: 10 AWG2.25 %voltage drop
Smallest metric: 4 mm²2.96 %voltage drop

Voltage drop is one check. The wire must also be rated for the current at its temperature and bundling, and the fuse must protect the wire.

Planning estimate from the formula below, not a measurement.

How it works

The formula, the method step by step, then a worked example.

V_drop = I × ρ_Cu(T) × L ÷ A;  ρ_Cu = 1.724×10⁻⁸ Ω·m × (1 + 0.00393 × (T − 20 °C))
  1. Copper resistance per metre comes from its resistivity and the conductor area (AWG areas per ASTM B258).
  2. Resistance rises with temperature.
  3. Drop is current × resistance × circuit length; include the return wire if the load is not grounded locally.

Worked example

Inputs

Load current
20 A
One-way run length (m)
4
Return path
0
System voltage
13.5 V
Maximum voltage drop
3 %
Conductor temperature
140 °F

Result

Smallest AWG: 10 AWG2.25%
Smallest metric: 4 mm²2.96%

Assumptions and limits

  • Solid-copper equivalent area; stranded automotive cable (SAE J1128 / ISO 6722) has similar resistance per area.
  • Does not size for ampacity or fuse rating.

Related terms

Frequently asked

What gauge wire do I need for 30 amps at 12 volts?

It depends on run length. For a 3 m one-way run grounded locally, 10 AWG (about 5.3 mm²) keeps drop under 3% at engine-bay temperatures; longer runs need thicker wire. Use the calculator for your length and allowed drop.

How much voltage drop is acceptable in a car?

Many automotive design guides target about 3% or less for critical loads such as fuel pumps, ignition and ECUs, and up to 10% for non-critical loads such as lighting. Lower drop also means less heat in the wire.

Does the fuse protect the device or the wire?

The fuse protects the wire. Choose a fuse rated at or below what the wire can safely carry at its temperature and bundling, and above the circuit's normal running current.

Answers draw on the sources below.

Sources

  1. ASTM B258: Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires · ASTM International
  2. SAE J1128: Low Voltage Primary Cable · SAE International

Spot an error? Tell us.