Voltage drop calculator for 12 V automotive wiring

Voltage drop = current × copper resistance of the circuit length. Pick the wire size, run length and current to see the drop in volts and percent against your target, the voltage at the load, the heat in the wire and the longest run that still passes.

A
in
V
°F

Copper resistance rises about 0.39% per °C; engine-bay wiring runs hot.

%

3% is a common limit for critical loads such as fuel pumps and ignition; 10% for non-critical loads.

Result

Voltage drop0.417 V
Drop as % of system voltage3.09 %over target
Voltage at the load13.08 V
Heat in the wire (W)8.3
Longest one-way run within target153 in
Circuit resistance (Ω)0.0208 Ω

Above your 3% target: use a larger wire, shorten the run or add a return wire only if the ground path is worse.

Planning estimate from the formula below, not a measurement.

How it works

The formula, the method step by step, then a worked example.

V_drop = I × ρ_Cu(T) × L ÷ A;  ρ_Cu(T) = 1.724×10⁻⁸ Ω·m × (1 + 0.00393 × (T − 20 °C));  % = V_drop ÷ V_system × 100
  1. Copper's resistivity at 20 °C is 1.724×10⁻⁸ Ω·m (the annealed-copper standard); it rises 0.393% per °C.
  2. Resistance of the circuit is resistivity × length ÷ conductor area. Count the return wire if the load is not grounded nearby.
  3. Drop is current × resistance; the wire turns drop × current into heat.
  4. Solve the same equation for length to find the longest run that meets your target.

Worked example

Inputs

Load current
20 A
Wire size
3.309
One-way run length
157.48 in
Return path
0
System voltage
13.5 V
Conductor temperature
68 °F
Target maximum drop
3 %

Result

Voltage drop0.417V
Drop as % of system voltage3.09%
Voltage at the load13.08V
Heat in the wire (W)8.3
Longest one-way run within target153in
Circuit resistance (Ω)0.0208Ω

Assumptions and limits

  • DC, steady current, copper conductor. Stranded automotive cable (SAE J1128, ISO 6722) has close to the same resistance per area as the solid-wire areas shown.
  • Terminals, splices, switches and the chassis ground add resistance that this does not include; measure it with a voltage-drop test under load.
  • Voltage drop is one check: the wire must also be rated for the current and protected by its fuse.

Related terms

Frequently asked

How do you calculate voltage drop?

Voltage drop = current × resistance of the wire. Resistance = copper resistivity × circuit length ÷ conductor area. For 20 A through 4 m of 12 AWG (3.31 mm²) at 20 °C, resistance is about 0.021 Ω and the drop is about 0.42 V, 3.1% of 13.5 V.

What is an acceptable voltage drop in a car?

A common target is 3% or less for critical loads such as fuel pumps, ignition and ECU feeds, and up to 10% for non-critical loads such as lighting. On a 13.5 V system, 3% is about 0.4 V.

Does temperature affect voltage drop?

Yes. Copper resistance rises about 0.39% per °C, so wire in a 60 °C engine bay has about 16% more resistance, and drop, than the same wire at 20 °C.

Do I count the ground wire in voltage drop?

Count every conductor the current flows through. If the load is grounded to the chassis next to it, use the feed length; if a return wire runs back to the battery or PDM, the circuit length doubles. Chassis grounds also add resistance, so test them under load.

Answers draw on the sources below.

Sources

  1. IEC 60028: International standard of resistance for copper (annealed copper, 1/58 Ω·mm²/m at 20 °C, 0.00393 /°C) · International Electrotechnical Commission
  2. ASTM B258: Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires · ASTM International · retrieved 2026-10-27
  3. SAE J1128: Low Voltage Primary Cable · SAE International · retrieved 2026-10-27

Spot an error? Tell us.