PDM channel fuse and wire size calculator

Size each power distribution module (PDM) output: fuse or current limit at the load ÷ 80%, rounded up to a standard size, then the smallest wire that both carries that fuse rating after heat and bundling derating and keeps voltage drop under your limit.

A
:1

Typical surge multipliers, used only to flag a PDM channel's inrush allowance. Check the load's own data.

%

80% is the common sizing rule: the fuse is 125% of the steady current.

in
%
V
°F
A
A
A

Result

Fuse or current-limit rating20.0 A
Recommended wire (mm²)2.08 14 AWG
Voltage drop with this wire0.37 V
Smallest for ampacity (mm²)1.31 16 AWG, 21.3 A derated
Smallest for voltage drop (mm²)2.08 14 AWG
Estimated start-up surge90 A
Channel load60 %
PDM total load60 %

Start-up surge exceeds the channel rating: check the PDM's inrush time allowance for this channel.

Planning estimate from the formula below, not a measurement.

How it works

The formula, the method step by step, then a worked example.

fuse ≥ I ÷ 0.80 (next standard size);  ampacity(105 °C) × 0.85 (engine space) × bundle factor ≥ fuse;  V_drop = I × ρ(T) × L ÷ A ≤ limit
  1. Divide the steady current by the allowed loading (80% by default) and round up to the next standard fuse size, or set the PDM channel's electronic current limit there.
  2. Pick the smallest wire whose allowable current, after the engine-space factor (0.85 for 105 °C insulation) and the bundling factor (0.70 for 3 wires, 0.60 for 4-6, 0.50 for 7-24), is at least the fuse rating, so the fuse protects the wire.
  3. Separately, find the smallest wire that keeps voltage drop under your limit at the steady current, using copper resistance at the conductor temperature.
  4. Use the larger of the two, then check the channel and total PDM loading.

Worked example

Inputs

Steady load current
15 A
Load type (start-up surge)
6 :1
Load as % of fuse rating
80 %
Wire length, one way
118.11 in
Return path
0
Maximum voltage drop
3 %
System voltage
13.5 V
Conductor temperature
68 °F
Run through the engine bay
1
Current-carrying wires in the bundle
1
PDM channel rating
25 A
All other channels, steady total
45 A
PDM total continuous rating
100 A

Result

Fuse or current-limit rating20.0A
Recommended wire (mm²)2.08
Voltage drop with this wire0.37V
Smallest for ampacity (mm²)1.31
Smallest for voltage drop (mm²)2.08
Estimated start-up surge90A
Channel load60%
PDM total load60%

Assumptions and limits

  • Ampacity values are the 105 °C column of 33 CFR 183.425 Table 5 (US boat wiring rule, from ABYC E-11). It is a published conservative reference, not an automotive standard; use the wire maker's data where you have it.
  • Copper conductor, AWG areas per ASTM B258; metric cable (mm²) of at least the shown area is equivalent.
  • Surge multipliers are typical values for flagging only. A PDM's electronic fuse trips on its own current-time curve.
  • Steady loads only; intermittent loads such as starter motors are outside this method.

Related terms

Frequently asked

What size fuse do I need for a 15 amp fuel pump?

Size the fuse so the steady current is no more than about 80% of its rating: 15 A ÷ 0.8 = 18.75 A, so a 20 A fuse or electronic current limit. The wire must then be rated to carry at least 20 A after derating for engine-bay heat and bundling.

Does the fuse protect the wire or the device?

The fuse protects the wire. Choose the wire so its allowable current, after heat and bundling derating, is at least the fuse rating; then a short circuit opens the fuse before the wire overheats. The device may need its own lower-rated protection.

Why is my wire bigger than the ampacity alone needs?

Long runs are usually limited by voltage drop, not heating. A pump 3 m from the PDM drawing 15 A loses about 0.6 V through 16 AWG, over 4% of 13.5 V, so the calculator steps up to 14 AWG to stay under a 3% drop.

Answers draw on the sources below.

Sources

  1. 33 CFR 183.425: Conductors: General (Table 5, allowable amperage of conductors; engine-space and bundling correction factors) · U.S. Code of Federal Regulations, via Cornell Legal Information Institute · retrieved 2026-10-27
  2. ISO 8820-3: Road vehicles - Fuse-links - Part 3: Fuse-links with tabs (blade type) · International Organization for Standardization · retrieved 2026-10-27
  3. ASTM B258: Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires · ASTM International · retrieved 2026-10-27
  4. Automotive Handbook · Robert Bosch GmbH

Spot an error? Tell us.