High-side switch

high side driverhigh-side outputsmart high-side switchHSDpositive switched output

A high-side switch is a switch placed between the positive supply and the load, with the load's other end connected to ground. When it turns on, the load receives battery voltage. Automotive high-side switches are usually MOSFET-based smart devices with current limiting, thermal shutdown and fault diagnostics built in.628

How it works

Switching the positive side means the load sits at ground potential when off.

A short from the wire to chassis is then harmless while the switch is off, and when on it is detected as overcurrent. That is why body and power distribution loads such as fuel pumps, fans and lamps are commonly switched on the high side.Medium261

An N-channel MOSFET has lower on-resistance than a P-channel of the same size, but used on the high side its gate must be driven above the supply voltage. Smart high-side switches include a charge pump for this. P-channel switches avoid the charge pump at the cost of higher losses.Medium86

Smart high-side switches add protection. TI's TPS1H100-Q1, a single-channel 40 V, 100 mΩ device, includes a programmable current limit, thermal shutdown with self-recovery, open-load and short-circuit detection, and a negative voltage clamp for switching inductive loads.6

Reverse battery needs extra attention with high-side switches. Their MOSFET body diode conducts when supply polarity is reversed, so designs add ground networks or blocking devices, as TI's application report on reverse battery protection for high-side switches describes.4

Typical values

On-resistance, TPS1H100-Q1
  • 80 mΩ typical, 100 mΩ max at 25 °C
  • 166 mΩ max at 150 °C
Resistance rises with temperatureSourced6
Operating voltage
  • 5-40 V nominal
  • Down to 3.5 V extended
TPS1H100-Q1Sourced6
Internal current limit7-13 A, about 10 A typicalExternal resistor can set a lower limitSourced6
Inductive clamp
  • 50-70 V drain-to-source
  • 70 mJ single pulse
TPS1H100-Q1Sourced6
Thermal shutdown175 °C (347 °F), resets at 155 °C311 °FTPS1H100-Q1 junction temperatureSourced6
Current sense ratio1/500 of load current, ±3% above 1 ATPS1H100-Q1 version BSourced6
Maximum PWM input frequency2kHzTPS1H100-Q1Sourced6
Motorsport PDM high-side channel15 A continuous, 100 A peakBosch PBX 190Sourced9

How an ECU uses it

ECUs use high-side outputs where a load needs battery positive, such as relay feeds and some valves, while injectors and coils are usually switched low-side. PDMs are almost entirely high-side, because body loads are grounded locally to chassis.Medium915

Smart high-side switches report load current as a small mirror current. The TPS1H100-Q1 sources 1/500 of load current on its sense pin, accurate to ±3% above 1 A, which the controller converts to amps for overload, open-load and pump or fan current logging.6

Off-state diagnostics find faults before the load is needed. With diagnostics enabled and an external pull-up fitted, the TPS1H100-Q1 flags an open load when the off output floats to within 1.4-2.6 V of supply.6

How to test it

5 checks, in order.

  1. Identify the output type from the module pinout. With the output on and the load unplugged, a high-side pin lights a test lamp connected to ground; a low-side pin lights a lamp connected to battery positive instead.Medium65
  2. Use a test lamp or small resistive load, not just a meter. A high-impedance meter can show full voltage on an output that cannot deliver real current.Medium13
  3. With the real load running, measure the drop from the module's supply pin to its output pin. Compare it with load current times R_DS(on); a much larger drop points to a failing switch or a bad connector.Medium613
  4. Compare the controller's current reading for the channel with a clamp meter on the load wire. Agreement within a few percent confirms the channel; a large gap points to configuration or a damaged sense path.Medium6
  5. Safety
    never test an output by shorting it to ground. Current limiting protects the switch, but repeated hard shorts drive it into thermal shutdown, and a short upstream of the output is not protected at all.Medium610

Symptoms and causes

Relay or solenoid never turns on

Likely causes Load wired for a low-side output, or an open-load fault latched

Check With the output on, check for battery voltage at the pin with a test lamp to ground.

Medium65

Output cuts out when a cold lamp or fan starts

Likely causes Inrush exceeds the current limit, or thermal shutdown triggers

Check Log channel current and fault status at switch-on.

Medium612

Output shows voltage but the load does nothing

Likely causes Open circuit in the load wire, connector or load ground

Check Read the open-load diagnostic, then check continuity from output pin to load and load ground to chassis.

Medium6

Switch fails after driving a large solenoid

Likely causes Inductive turn-off energy beyond the clamp rating

Check Compare the coil's stored energy with the clamp energy rating; add a freewheel diode.

Medium67

In tuning

Check whether each controller output sources positive voltage (high side) or switches to ground (low side) before wiring a relay, solenoid or lamp. A load wired for the wrong type will either never turn on or stay on.Medium65

When a high-side output drives an inductive load such as a solenoid or relay coil, the switch must clamp the negative voltage spike at turn-off. Smart switches do this internally; otherwise add a flyback diode across the load.67

Formula and worked example

P = I² × R_DS(on)
P
power dissipated in the switchW
I
load currentA
R_DS(on)
switch on-resistance at operating temperatureΩ
86

Try it

A
:1

Typical surge multipliers, used only to flag a PDM channel's inrush allowance. Check the load's own data.

%

80% is the common sizing rule: the fuse is 125% of the steady current.

in
%
V
°F
A
A
A

Result

Fuse or current-limit rating20.0 A
Recommended wire (mm²)2.08 14 AWG
Voltage drop with this wire0.37 V
Smallest for ampacity (mm²)1.31 16 AWG, 21.3 A derated
Smallest for voltage drop (mm²)2.08 14 AWG
Estimated start-up surge90 A
Channel load60 %
PDM total load60 %

Start-up surge exceeds the channel rating: check the PDM's inrush time allowance for this channel.

Planning estimate from the formula below, not a measurement.

Open the full pdm channel fuse and wire size calculator →

Common mistakes

Mistake Treating the current rating as continuous at any temperature.

Do instead On-resistance rises about 66% from 25 °C to 150 °C in the TPS1H100-Q1; check I² × R_DS(on) at the hottest condition.6

Mistake Paralleling two outputs for a bigger load without checking the datasheet.

Do instead Only parallel channels the maker allows; Bosch pairs its 40 A PBX 190 channels for up to 80 A by design.Medium9

Mistake Returning high-side loads to the controller's ground pins.

Do instead Ground them to chassis or the star point so load current stays out of the controller's ground.Medium111

Myths vs facts

Myth High-side and low-side switching are interchangeable.

Fact They behave differently. A high-side switch feeds positive voltage to a grounded load; a low-side switch completes the ground path for a load fed from positive. Wiring, fault behavior and diagnostics differ.36

Myth A high-side output can drive any load up to its current rating forever.

Fact Continuous current is limited by power dissipated in the switch, I² × R_DS(on), and by ambient temperature. Lamps and motors also draw several times their running current at switch-on.Medium68

Frequently asked

What is a high side switch?

A high side switch connects a load to the positive supply, with the load's other end permanently grounded. When it turns on, the load sees battery voltage. In cars it is usually a smart MOSFET device with current limiting, thermal shutdown, current sensing and fault reporting, used for pumps, fans and lamps.62

What is the difference between high-side and low-side switching?

A high-side switch sits between battery positive and the load, and the load is grounded. A low-side switch sits between the load and ground, and the load is permanently fed from positive. High-side is common for power loads; low-side is common for injectors, ignition drivers and relay coils driven by engine controllers.Medium365

Why use a high-side switch?

With the switch on the positive side, the load wiring is at ground when off, so a chafed wire touching chassis does nothing until the output turns on and then trips the current limit. Smart high-side switches also provide current sensing and fault reporting, which suits fuel pumps, fans and lighting.Medium26

How does a high-side MOSFET switch work?

The MOSFET connects the supply to the load when its gate is driven on. For an N-channel device on the high side, the gate must be raised above the supply voltage, so smart switches include a charge pump. Integrated sensing then measures current and turns the MOSFET off on overload or overheating.Medium86

Can a high-side switch drive a solenoid?

Yes, provided it can handle the inductive kick at turn-off. When current is interrupted, the coil drives the output negative. Smart high-side switches clamp this internally; a TI example lists an inductive load negative voltage clamp. Without one, fit a flyback diode across the coil.67

Sources

Numbered as cited above. Hover or tap a citation chip to preview it.

13 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-10-27
  2. High-side switches product family · Infineon Technologies · vendor-doc · retrieved 2026-10-27
  3. Smart power switches (high-side and low-side) product family overview · Infineon Technologies · vendor-doc · retrieved 2026-10-27
  4. Reverse battery protection for high side switches (SLVAE55) · Texas Instruments · vendor-doc · retrieved 2026-10-27
  5. TPL7407L 40-V 7-channel low side driver data sheet (SLRS066) · Texas Instruments · vendor-doc · retrieved 2026-10-27
  6. TPS1H100-Q1 40-V, 100-mOhm single-channel smart high-side power switch data sheet · Texas Instruments · vendor-doc · retrieved 2026-10-27
  7. Flyback diode · Wikipedia · reference · retrieved 2026-10-27
  8. Power MOSFET · Wikipedia · reference · retrieved 2026-10-27
  9. PowerBox PBX 190 data sheet 75077387 · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
  10. Fuse (electrical) · Wikipedia · reference · retrieved 2026-10-27
  11. Ground (electricity) · Wikipedia · reference · retrieved 2026-10-27
  12. Inrush current · Wikipedia · reference · retrieved 2026-10-27
  13. Voltage drop · Wikipedia · reference · retrieved 2026-10-27