How it works
Switching the positive side means the load sits at ground potential when off.
A short from the wire to chassis is then harmless while the switch is off, and when on it is detected as overcurrent. That is why body and power distribution loads such as fuel pumps, fans and lamps are commonly switched on the high side.Medium261
An N-channel MOSFET has lower on-resistance than a P-channel of the same size, but used on the high side its gate must be driven above the supply voltage. Smart high-side switches include a charge pump for this. P-channel switches avoid the charge pump at the cost of higher losses.Medium86
Smart high-side switches add protection. TI's TPS1H100-Q1, a single-channel 40 V, 100 mΩ device, includes a programmable current limit, thermal shutdown with self-recovery, open-load and short-circuit detection, and a negative voltage clamp for switching inductive loads.6
Reverse battery needs extra attention with high-side switches. Their MOSFET body diode conducts when supply polarity is reversed, so designs add ground networks or blocking devices, as TI's application report on reverse battery protection for high-side switches describes.4
Typical values
- 80 mΩ typical, 100 mΩ max at 25 °C
- 166 mΩ max at 150 °C
How an ECU uses it
ECUs use high-side outputs where a load needs battery positive, such as relay feeds and some valves, while injectors and coils are usually switched low-side. PDMs are almost entirely high-side, because body loads are grounded locally to chassis.Medium915
Smart high-side switches report load current as a small mirror current. The TPS1H100-Q1 sources 1/500 of load current on its sense pin, accurate to ±3% above 1 A, which the controller converts to amps for overload, open-load and pump or fan current logging.6
Off-state diagnostics find faults before the load is needed. With diagnostics enabled and an external pull-up fitted, the TPS1H100-Q1 flags an open load when the off output floats to within 1.4-2.6 V of supply.6
How to test it
5 checks, in order.
- Use a test lamp or small resistive load, not just a meter. A high-impedance meter can show full voltage on an output that cannot deliver real current.Medium13
- Compare the controller's current reading for the channel with a clamp meter on the load wire. Agreement within a few percent confirms the channel; a large gap points to configuration or a damaged sense path.Medium6
Symptoms and causes
Relay or solenoid never turns on
Likely causes Load wired for a low-side output, or an open-load fault latched
Check With the output on, check for battery voltage at the pin with a test lamp to ground.
Output cuts out when a cold lamp or fan starts
Likely causes Inrush exceeds the current limit, or thermal shutdown triggers
Check Log channel current and fault status at switch-on.
Output shows voltage but the load does nothing
Likely causes Open circuit in the load wire, connector or load ground
Check Read the open-load diagnostic, then check continuity from output pin to load and load ground to chassis.
Medium6
In tuning
Check whether each controller output sources positive voltage (high side) or switches to ground (low side) before wiring a relay, solenoid or lamp. A load wired for the wrong type will either never turn on or stay on.Medium65
When a high-side output drives an inductive load such as a solenoid or relay coil, the switch must clamp the negative voltage spike at turn-off. Smart switches do this internally; otherwise add a flyback diode across the load.67
Formula and worked example
P = I² × R_DS(on)
- P
- power dissipated in the switchW
- I
- load currentA
- R_DS(on)
- switch on-resistance at operating temperatureΩ
Try it
Result
Start-up surge exceeds the channel rating: check the PDM's inrush time allowance for this channel.
Planning estimate from the formula below, not a measurement.
Common mistakes
Mistake Treating the current rating as continuous at any temperature.
Do instead On-resistance rises about 66% from 25 °C to 150 °C in the TPS1H100-Q1; check I² × R_DS(on) at the hottest condition.6
Mistake Paralleling two outputs for a bigger load without checking the datasheet.
Do instead Only parallel channels the maker allows; Bosch pairs its 40 A PBX 190 channels for up to 80 A by design.Medium9
Myths vs facts
Frequently asked
What is a high side switch?
A high side switch connects a load to the positive supply, with the load's other end permanently grounded. When it turns on, the load sees battery voltage. In cars it is usually a smart MOSFET device with current limiting, thermal shutdown, current sensing and fault reporting, used for pumps, fans and lamps.62
What is the difference between high-side and low-side switching?
A high-side switch sits between battery positive and the load, and the load is grounded. A low-side switch sits between the load and ground, and the load is permanently fed from positive. High-side is common for power loads; low-side is common for injectors, ignition drivers and relay coils driven by engine controllers.Medium365
Why use a high-side switch?
With the switch on the positive side, the load wiring is at ground when off, so a chafed wire touching chassis does nothing until the output turns on and then trips the current limit. Smart high-side switches also provide current sensing and fault reporting, which suits fuel pumps, fans and lighting.Medium26
How does a high-side MOSFET switch work?
The MOSFET connects the supply to the load when its gate is driven on. For an N-channel device on the high side, the gate must be raised above the supply voltage, so smart switches include a charge pump. Integrated sensing then measures current and turns the MOSFET off on overload or overheating.Medium86
Can a high-side switch drive a solenoid?
Yes, provided it can handle the inductive kick at turn-off. When current is interrupted, the coil drives the output negative. Smart high-side switches clamp this internally; a TI example lists an inductive load negative voltage clamp. Without one, fit a flyback diode across the coil.67
Sources
Numbered as cited above. Hover or tap a citation chip to preview it.
13 sources
- Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-10-27
- High-side switches product family · Infineon Technologies · vendor-doc · retrieved 2026-10-27
- Smart power switches (high-side and low-side) product family overview · Infineon Technologies · vendor-doc · retrieved 2026-10-27
- Reverse battery protection for high side switches (SLVAE55) · Texas Instruments · vendor-doc · retrieved 2026-10-27
- TPL7407L 40-V 7-channel low side driver data sheet (SLRS066) · Texas Instruments · vendor-doc · retrieved 2026-10-27
- TPS1H100-Q1 40-V, 100-mOhm single-channel smart high-side power switch data sheet · Texas Instruments · vendor-doc · retrieved 2026-10-27
- Flyback diode · Wikipedia · reference · retrieved 2026-10-27
- Power MOSFET · Wikipedia · reference · retrieved 2026-10-27
- PowerBox PBX 190 data sheet 75077387 · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
- Fuse (electrical) · Wikipedia · reference · retrieved 2026-10-27
- Ground (electricity) · Wikipedia · reference · retrieved 2026-10-27
- Inrush current · Wikipedia · reference · retrieved 2026-10-27
- Voltage drop · Wikipedia · reference · retrieved 2026-10-27