How it works
Inside a typical solid state relay, the control input lights an infrared LED that is optically coupled to the output stage, so the control side is isolated from the load. The output is a triac or thyristor pair for AC loads, or one or more MOSFETs for DC loads. Packaged units reach roughly 100 A.Medium158
Thyristor and triac outputs only turn off when load current passes through zero, and zero-cross types also wait for a voltage zero to turn on. That softens lamp and motor inrush on AC mains. On DC there is no zero crossing, so a 12 V vehicle circuit needs a MOSFET-output DC relay.Medium153
A conducting semiconductor is not a closed contact. A MOSFET output behaves like a resistance, R_ON, and heats by I² × R_ON, while a thyristor output drops a roughly fixed forward voltage and heats in proportion to current. Either way a high-current SSR needs a heat sink and derating with temperature.Medium15813
Off does not mean open. Every SSR leaks a small current through its output when off, enough to keep an LED lamp or another relay input partly energized. Omron's remedy is a bleeder resistor across the load, and it notes MOSFET outputs suit very small loads directly.Medium53
In vehicles the modern form of the SSR is the smart high-side switch. TI's TPS1H100-Q1 combines a 100 mΩ MOSFET with current limiting, thermal shutdown, an inductive clamp and fault reporting, and leaks no more than 3 µA when off. Power distribution modules group dozens of such channels in place of relays.72
Typical values
- 0.5 µA max at 25 °C77 °F
- 3 µA at 125 °C257 °F
- 80 mΩ typical, 100 mΩ max at 25 °C
- Up to 166 mΩ at 150 °C302 °F
How an ECU uses it
Engine controllers rarely switch big loads directly.
They drive a relay coil or the input of a solid state switch from a low-side or high-side output, and the relay or SSR carries the pump, fan or heater current. Check whether the SSR input expects a positive signal or a ground.Medium176
A power distribution module is effectively a bank of programmable solid state relays. Each channel has its own current limit, retry rule and PWM ability, and the module reports current and faults over CAN, so the ECU or dash sees a failed fan or pump instead of guessing.Medium27
Because a MOSFET SSR switches quickly and does not wear, it can pulse-width modulate a pump or fan for speed control, which a mechanical relay cannot do for long. Stay within the device's PWM limit; TI rates the TPS1H100-Q1 input at 2 kHz maximum.157
How to test it
5 checks, in order.
Symptoms and causes
Load stays on or glows dimly when switched off
Likely causes Off-state leakage into a high-impedance load such as LEDs, or an AC triac SSR used on DC
Check Measure load voltage with the input off, then add a bleeder resistor; if the load still runs, confirm the SSR is a DC type.
SSR cuts out after several minutes at full load
Likely causes Thermal shutdown from I²R heating, missing heat sink or high ambient temperature
Check Log case temperature and voltage drop; a cut-out that tracks temperature is thermal, not electrical.
Load never turns on
Likely causes Input polarity wrong, input voltage below threshold, or output stage failed open after an overload
Check Measure input voltage at the SSR terminals while commanded on; if it is correct and the output drop equals supply voltage, the output is open.
Medium7
In tuning
Size an SSR for inrush, not running current.
A cold lamp or stalled motor draws many times its rated current, and an SSR cannot ride through overload the way relay contacts can. Pick a part whose surge rating covers the inrush, or one with active current limiting.Medium15312
For inductive loads such as pumps, solenoids and fans, confirm the SSR has an internal clamp or fit a flyback diode across the load. Vishay specifies a freewheel diode across inductive loads on its DC SSRs; without one the turn-off spike can exceed the output rating.810
Try it
Result
Start-up surge exceeds the channel rating: check the PDM's inrush time allowance for this channel.
Planning estimate from the formula below, not a measurement.
Common mistakes
Mistake Using an AC triac SSR on a 12 V DC load.
Do instead Use a DC-output MOSFET SSR or a smart high-side switch. A triac has no current zero to turn off at on DC.Medium15
Mistake Mounting a 40 A SSR without a heat sink because the label says 40 A.
Do instead The rating assumes a heat sink. Derate for ambient temperature and check case temperature at full load.Medium158
Myths vs facts
Myth A solid state relay is a drop-in replacement for any mechanical relay.
Fact It is specific to AC or DC and to load type, drops voltage, makes heat and leaks current when off. A five-pin automotive relay also offers a changeover contact that a single SSR output does not.Medium15145
Frequently asked
How does a solid state relay work?
A small control current lights an LED or drives a gate circuit inside the relay. That turns on a semiconductor output, a MOSFET for DC or a triac or thyristor pair for AC, which connects the load. With no moving parts, switching is silent, bounce-free and fast.Medium15
Is a solid state relay better than a mechanical relay?
It depends on the job. An SSR wins for fast or frequent switching, PWM speed control, vibration and life. A mechanical relay wins on cost, overload tolerance, near-zero off leakage and lower heat at high current. In cars, smart high-side switches now combine both roles with fuse-like protection.Medium15147
Can a solid state relay switch DC?
Yes, if it is a DC-output type. DC solid state relays use MOSFETs or IGBTs that can turn off at any moment. AC types use triacs or thyristors that only turn off when current crosses zero, so on a DC circuit they can stay latched on.Medium158
Why does my solid state relay get hot?
Its output is a semiconductor, not a metal contact, so load current through its on-resistance or forward drop turns into heat. A MOSFET at 10 A and 10 mΩ dissipates 1 W; at 100 mΩ it dissipates 10 W. High-current SSRs need a heat sink and derating.138
Do solid state relays fail open or closed?
They can fail either way, but a shorted output is a common result of overcurrent, overheating or a voltage spike, leaving the load stuck on. That is why the feed still needs a fuse and why fuel pumps and heaters need an independent way to shut down.Medium411
Sources
Numbered as cited above. Hover or tap a citation chip to preview it.
16 sources
- Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-10-27
- PowerBox PBX 190 data sheet 75077387 · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
- Application of solid state relays (S/GEN/APPLICATIONS/A) · celduc relais · vendor-doc · retrieved 2026-10-27
- Smart power switches (high-side and low-side) product family overview · Infineon Technologies · vendor-doc · retrieved 2026-10-27
- FAQ: SSR leakage current and load reset failure (FAQ02155) · OMRON Industrial Automation · vendor-doc · retrieved 2026-10-27
- TPL7407L 40-V 7-channel low side driver data sheet (SLRS066) · Texas Instruments · vendor-doc · retrieved 2026-10-27
- TPS1H100-Q1 40-V, 100-mOhm single-channel smart high-side power switch data sheet · Texas Instruments · vendor-doc · retrieved 2026-10-27
- Design considerations on solid-state relays in DC configuration (Application Note 09, document 80312) · Vishay Semiconductors · vendor-doc · retrieved 2026-10-27
- Ampacity · Wikipedia · reference · retrieved 2026-10-27
- Flyback diode · Wikipedia · reference · retrieved 2026-10-27
- Fuse (electrical) · Wikipedia · reference · retrieved 2026-10-27
- Inrush current · Wikipedia · reference · retrieved 2026-10-27
- Power MOSFET · Wikipedia · reference · retrieved 2026-10-27
- Relay · Wikipedia · reference · retrieved 2026-10-27
- Solid-state relay · Wikipedia · reference · retrieved 2026-10-27
- Voltage drop · Wikipedia · reference · retrieved 2026-10-27