MoTeC · Wideband controllers

MoTeC LTC (Lambda to CAN)

CAN expansion modules

The MoTeC LTC (Lambda to CAN) is a small wideband controller that runs a Bosch LSU 4.9 sensor and sends lambda readings over CAN to an ECU or logger. At 60 g and 38 × 26 × 14 mm it mounts near the sensor. Up to 32 sensors can share one CAN bus, and dual (LTCD) and NTK-sensor versions exist.12

λ
Illustration, not the product.

Key facts

Sensor1 × Bosch LSU 4.9LTCSourced1
OutputCAN, 125 kbps to 1 MbpsSourced1
Sensors per busUp to 32Sourced1
Size and weight38 × 26 × 14mm, 60 g2.1 ozSourced1
Supply11-16 V, 110 mA + heaterup to 2 A at startSourced1

Suits

  • MoTeC M1 and C-series systems needing lambda on CAN
  • Race engines logging lambda per cylinder or per bank
  • Installs where a small controller must sit close to the sensor

What it is and where it fits

The MoTeC LTC monitors, controls and diagnoses a Bosch LSU 4.9 wideband sensor and transmits lambda on CAN.

It has no display or analog output on the base unit; an ECU, dash or logger reads its messages.1

It fits multi-sensor installs well. Up to 32 lambda sensors can share one CAN bus, which allows per-cylinder or per-bank lambda on race engines.1

MoTeC lists M1-series and older M84 to M880 ECUs, all C-series display loggers, the ACL and CDL3 as compatible. Other systems can read it only if they can decode its CAN messages.Medium1

Hardware and I/O

The case measures 38 × 26 × 14 mm (1.5 × 1.0 × 0.6 in) and weighs 60 g, small enough to mount close to the sensor.

A 4-pin DTM connector carries power and CAN, and the sensor plugs straight into the unit.1

Supply is 11 to 16 V. The unit draws about 110 mA plus the sensor heater, which typically takes 0.5 to 1 A and up to 2 A during warm-up.1

The LSU 4.9 sensor reads from lambda 0.65 to free air. Bosch specifies accuracy of 1.016 ± 0.007 at lambda 1 and 0.80 ± 0.01 at lambda 0.8, and exhaust gas below 930 °C in normal use.3

Software and configuration

An LTC ships set up for a single-unit install, using the sensor's factory calibration and CAN address 460.

LTC Manager software is only needed for multiple units or changed settings.1

LTC Manager configures and calibrates every unit on the bus, shows readings and diagnostics, sets CAN addresses, runs free-air calibration and updates firmware. MoTeC notes the controller stays accurate when exhaust temperature is changing quickly.1

Current 61800-series units need LTC Manager 1.3.0.0079 (64-bit) or later. They work alongside older 61300-series units in the same installation.1

Connectivity and expansion

The CAN bit rate is selectable at 125 kbps, 250 kbps, 500 kbps or 1 Mbps.

Each additional LTC needs its own CAN address set in LTC Manager.1

A laptop reaches the LTC through a MoTeC gateway: an M1 ECU, a C-series display logger, an ACL, ADL3, SDL3 or CDL3, or the UTC USB-to-CAN interface (#61059).1

Installation notes

MoTeC suggests powering the LTC from the ignition switch for fast sensor start-up, or from the fuel pump relay to avoid draining the battery. Ambient temperature at the unit must stay below 100 °C (212 °F).1

Bosch lists 40 to 60 N·m (30 to 44 lbf·ft) tightening torque for the LSU 4.9 and a 22 mm wrench. Keep the sensor connector below 140 °C and the wire sleeve below 250 °C.3

Long versions (61800L, 61801L, 61805L) suit installs where the electronics must sit further from the sensor.Medium2

Generations and variants

MoTeC changed LTC part numbers from 61 3XX to 61 8XX with no functional difference.

The range now includes the single LTC, the dual-sensor LTCD, long-loom versions and NTK-sensor versions (LTC NTK and LTCD NTK).12

Units marked 2 or higher under the barcode can transmit extended rich lambda values, which matters for engines run very rich, such as on methanol.Medium1

Specifications

From the maker's published data and independent sources.

Electrical and communication

SpecValueSource
Sensor input1 × Bosch LSU 4.9 wideband sensor1
Supply voltage11-16 V1
Supply current110 mA typical plus heater; heater typically 0.5-1 A, up to 2 A at startup1
CAN1 bus at 125 kbps, 250 kbps, 500 kbps or 1 Mbps1
Default setupFactory sensor calibration, CAN address 4601
Rich lambdaUnits marked 2 or higher under the barcode can send extended (rich) lambda values1

Physical

SpecValueSource
Dimensions38 × 26 × 14 mm (1.50 × 1.02 × 0.55 in), excluding looms and connectors1
Weight60 g (2.1 oz)1
Connectors4-pin male DTM for power and CAN; mating connector for the LSU 4.9 sensor1
Maximum ambient temperature100 °C (212 °F)1
Part numbersLTC 61800, LTC Long 61800L, LTCD 61801, LTCD Long 61801L, LTC NTK 61804, LTCD NTK 61805, LTCD NTK Long 61805L2

Sensor (Bosch LSU 4.9)

SpecValueSource
Measuring rangeLambda 0.65 to free air3
Sensor accuracy1.016 ± 0.007 at lambda 1; 0.80 ± 0.01 at lambda 0.83
Exhaust gas temperatureUnder 930 °C (1,706 °F) operating; 1,030 °C briefly3
FuelsGasoline, diesel and E853

Strengths and limits

Facts, each cited. Not a score.

Strengths

  • Up to 32 sensors on one CAN bus for per-cylinder or per-bank lambda.1
  • Small and light at 38 × 26 × 14 mm and 60 g.1
  • Ships pre-configured for a single install; free-air or factory calibration selectable.1

Limits

  • CAN output only on the base LTC; there is no analog voltage output or display listed.Medium1
  • PC access needs a MoTeC gateway device or the UTC interface.1
  • Older units without the 2 marking cannot send extended rich lambda values.1

Often compared with

ProductCategoryKey fact
ECUMaster Lambda to CANWideband controllersSensor: Bosch LSU 4.9
14Point7 Spartan 3Wideband controllersSensors: Bosch LSU 4.9, LSU ADV, clone LSU 4.9

Frequently asked

What is a MoTeC LTC?

LTC stands for Lambda to CAN. It is a MoTeC wideband controller that runs a Bosch LSU 4.9 sensor and sends lambda readings on a CAN bus to an ECU, dash or logger. It weighs 60 g and measures 38 × 26 × 14 mm, so it mounts close to the sensor.1

What is the difference between the MoTeC LTC and LTCD?

The LTCD is the dual version, running two lambda sensors from one unit, while the LTC runs one. Both come in long-loom versions, and NTK-sensor versions exist as LTC NTK and LTCD NTK. Part numbers are 61800 for the LTC and 61801 for the LTCD.21

How many MoTeC LTC units can be on one CAN bus?

MoTeC states that up to 32 lambda sensors can be configured on a single CAN bus when using multiple LTCs. Each unit needs its own CAN address, set in LTC Manager software. A single unit ships ready to use at the default address of 460.1

How do you calibrate a MoTeC LTC?

By default the LTC uses the sensor's factory calibration. LTC Manager can run a free-air calibration instead, with the sensor out of the exhaust in clean air. The same software sets CAN addresses and bit rate, shows diagnostics and updates firmware.1

What sensor does the MoTeC LTC use?

The standard LTC runs a Bosch LSU 4.9 wideband sensor, which reads from lambda 0.65 to free air on gasoline, diesel and E85. MoTeC also sells LTC NTK and LTCD NTK versions for NTK sensors.132

Does the MoTeC LTC work with non-MoTeC ECUs?

MoTeC lists only its own ECUs and display loggers as compatible. The LTC sends standard CAN messages, so another ECU or logger can use it if it can be set up to decode those messages. Confirm with the receiving device's maker before buying.Medium1

Related terms

Sources

Numbered as cited above. Hover or tap a citation chip to preview it.

  1. LTC (Lambda to CAN) product page, part 61800 · MoTeC · vendor-doc · retrieved 2026-11-04
  2. Lambda Measurement product category · MoTeC · vendor-doc · retrieved 2026-11-04
  3. Lambda Sensor LSU 4.9 data sheet 69034379 · Bosch Motorsport · vendor-doc · retrieved 2026-11-04

A technical overview from published sources; we have not tested this product. Product names are the property of their owners and identify the product only; GAINS is not affiliated with, or endorsed by, the maker.