Bosch · Analog 0-5 V (ratiometric)

Bosch PST-F 1 fuel pressure and temperature sensor (10 bar)

Bosch 0 261 544 01F

The Bosch PST-F 1 measures relative fuel pressure (0-10 bar) and fuel temperature in port-injection systems. Pressure output is 0.5-4.5 V ratiometric, 400 mV per bar plus 500 mV at 5 V. The temperature NTC reads 2,480 Ω at 20 °C; Bosch suggests a 4.6 kΩ pull-up for it. It seals with a cone in an M10x1 port.2

Key specifications

Measures: Relative fuel pressure (0-10 bar) and fuel temperature (-40 to 150 °C). Output: Analog 0-5 V (ratiometric).

Pressure range
  • 0-10 bar relative
  • 20 bar max 15 min
  • Burst 40 bar
Sourced2
Output0.5-4.5V ratiometricSourced2
Sensitivity / offset
  • 400 mV/bar
  • 500 mV at 5 V
Sourced2
Tolerance± 1.2 % FS at 0-100 °CSourced2
Thread / torqueM10x1, 27 mm, 24 N·m, sealed coneSourced2
Temperature pull-up4.6kΩ recommendedSourced2
Part numberMakerNote
0 261 544 01FBoschPrinted as 0261.544.01F on the data sheet2

Pinout and connector

12345Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
2Pressure signalAnalog voltage input (pull-up off)—
3Power supply (5 V)+5 V sensor reference—
4GroundSensor groundReturn to sensor ground, not chassis
5Temperature signalTemperature input (pull-up on)—

Pin functions as published.2 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Trapezoid; mating part F02U.B00.751-012 Connector library

Terminals and seals: Not listed: the Bosch data sheet gives the mating housing only, not contact or seal part numbers.

Transfer function and calibration data

Pressure transfer at 5 V2

Ua = 0.5 V + 0.4 V/bar × p (at Us = 5 V)

0.51.52.53.54.502.557.510Relative pressure (bar)Output (V)

Points computed from Bosch's sensitivity and offset.

Show the 6 data points
Relative pressure (bar)Output (V)
00.5
21.3
42.1
62.9
83.7
104.5
Temperature sensor (NTC)2
1001,00010,000-407.555102.5150Temperature (°C)Resistance (Ω), log scale
Show the 19 data points
Temperature (°C)Resistance (Ω)
-4044,864
-3025,524
-2015,067
-109,195
05,784
103,740
202,480
301,683
401,167
50824
60594
70434.9
80323.4
90244
100186.6
110144.5
120113.3
13089.9
15058.1

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.5–4.5 V → 0–1,000 kPa relative (maker: Ua = 0.5 V + 0.4 V/bar × p (at Us = 5 V))2Calculated from the maker's data
  • NTC: 44,864 Ω at -40 °C falling to 58.1 Ω at 150 °C2
  • Steinhart-Hart fit through -40 °C, 50 °C, 150 °C: A = 1.2905e-3, B = 2.6140e-4, C = 1.6159e-7 (largest error against the maker's table 0.12 °C).2Calculated from the maker's data

Worked conversion

  • At 2.5 V the maker's transfer line gives 500 kPa relative (72.5 psi).2Calculated from the maker's data
  • At 20 °C the element is 2,480 Ω; with a 4.6 kΩ pull-up to 5 V the ECU sees 5 × 2,480 / (2,480 + 4,600) = 1.751 V.22Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (17 rows)Calculated from the maker's data
Output (V)Pressure (kPa relative)Pressure (psi)
0.500
0.7562.59.06
112518.13
1.25187.527.19
1.525036.26
1.75312.545.32
237554.39
2.25437.563.45
2.550072.52
2.75562.581.58
362590.65
3.25687.599.71
3.5750108.78
3.75812.5117.84
4875126.91
4.25937.5135.97
4.51000145.04

Interpolated between the maker's published points; nominal values with no tolerance band.

Temperature sensor (NTC): resistance and ECU input voltage (19 rows)Calculated from the maker's data
Temperature (°C)Resistance (Ω)V at 4.6 kΩ pull-up to 5 V
-40448644.535
-30255244.236
-20150673.831
-1091953.333
057842.785
1037402.242
2024801.751
3016831.339
4011671.012
508240.76
605940.572
70434.90.432
80323.40.328
902440.252
100186.60.195
110144.50.152
120113.30.12
13089.90.096
15058.10.062

Resistance from the maker's table; voltages calculated for the maker-recommended pull-up.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium3
Haltech (Elite / Nexus)Configurable (generic input)Analog voltage input (AVI). Haltech's wiring diagram says inputs are user definable in software; enter the maker's transfer function.78
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium9
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). MoTeC's sensor pages show a manual-calibration option in M1 Tune.Medium1011
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs. ECUMaster lists user-defined sensor characteristics for some functions.Medium12
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium13
MaxxECUConfigurable (generic input)Extra 0-5 V input (6 on the RACE). The public page does not describe calibration entry.Medium14
Holley (Terminator X / EFI)Configurable (generic input)'5' analog input, set up as a custom sensor in Holley's software (per the wiring manual).15

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Fuel work carries fire risk: depressurise the system, use the specified sealing cone and torque, and leak-check with the pump primed.Medium21

Failure modes and checks

Fuel temperature wrong

Likely cause Pull-up not set to the recommended value

Check Use about 4.6 kΩ on the temperature input, or enter the actual pull-up in the ECU table.Medium2

Pressure reads 0.5 V with pump running

Likely cause Sensor not seeing rail pressure (blocked port) or reference vent blocked

Check Check the port and the sensor's reference opening.Medium2

Test it with a multimeter

  • Key on, engine off, system depressurised: back-probe signal to sensor ground and expect about 0.5 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data
  • Unplugged, measure resistance across the two element pins: about 2,480 Ω at 20 °C, falling as it warms (compare with the table).2Calculated from the maker's data

Frequently asked

What is the pinout of the Bosch PST-F 1?

Pin 2 pressure signal, pin 3 5 V supply, pin 4 ground, pin 5 temperature signal, on a Bosch Trapezoid connector.2

Is the PST-F 1 absolute or relative?

Relative: it references atmosphere through an opening in the housing, so it reads zero with no fuel pressure.2

Related

Use it with GAINS

Bosch PST-F 1 fuel pressure and temperature sensor (10 bar) on GAINS hardware

ECU2AVI pressure (pull-up off) + AVI temperature (pull-up on)

Pins
On the ECU2 pin map
Pull-up
To be confirmed
Shielding
Not needed

Two analog inputs: pressure with the pull-up off, temperature with it on.Medium3

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

15 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-10-27
  2. Pressure Sensor Combined PST-F 1 data sheet 70496907 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-10-27
  3. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  4. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  5. PST F 1 product page · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
  6. Nexus R3 wiring diagram (HT-193000_WD) · Haltech · vendor-doc · retrieved 2026-10-27
  7. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-10-27
  8. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  9. TMAP Sensor product page · MoTeC · vendor-doc · retrieved 2026-10-27
  10. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-10-27
  11. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  12. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-10-27
  13. HP / Dominator EFI wiring manual 199R10555 · Holley · vendor-doc · retrieved 2026-10-27

Not yet indexed: fewer than 3 FAQs.