Honeywell · Analog 0-5 V (ratiometric)
Honeywell PX3 100 psi sealed-gage pressure transducer (PX3AN1BH100PSAAX)
PX3AN1BH100PSAAX is a Honeywell PX3 heavy-duty pressure transducer: 0-100 psi (6.9 bar) sealed gage, 0.5-4.5 V ratiometric output, 1/4-18 NPT brass port, HNBR seal rated -30 to 135 °C and a Metri-Pack 150 connector. Its 100 psi span fits typical engine oil and port-injection fuel pressure. Honeywell's nomenclature defines each code; the pin assignment is not in the document we archived.2
Key specifications
Measures: Sealed-gage pressure, 0-100 psi (0-6.9 bar). Output: Analog 0-5 V (ratiometric).
| Part number | Maker | Note |
|---|---|---|
| PX3AN1BH100PSAAX | Honeywell | Metri-Pack 150, 1/4-18 NPT, brass, HNBR seal, 100 psi, sealed gage, 0.5-4.5 V ratiometric (decoded from Honeywell's nomenclature)2 |
Pinout and connector
No pinout is shown: the maker or OEM does not publish one in a document we could cite. Identify pins with a meter before wiring.
Connector: Aptiv (Delphi) Metri-Pack 150, 3-way; mating part Honeywell cable 3685301 (1 m) or 3685302 (3 m)2 Connector library
Terminals and seals: Not listed in the nomenclature sheet.
Transfer function and calibration data
Ua = 0.5 V + 0.04 V/psi × p (nominal, at 5 V supply)
Points computed from Honeywell's 0.5-4.5 V output code across the 0-100 psi range; accuracy limits not shown.
Show the 5 data points
| Pressure (psi) | Output (V) |
|---|---|
| 0 | 0.5 |
| 25 | 1.5 |
| 50 | 2.5 |
| 75 | 3.5 |
| 100 | 4.5 |
How it's calibrated
ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.
Transfer function
- 0.5–4.5 V → 0–689 kPa (maker: Ua = 0.5 V + 0.04 V/psi × p (nominal, at 5 V supply))2Calculated from the maker's data
Worked conversion
- At 2.5 V the maker's transfer line gives 345 kPa (50 psi).2Calculated from the maker's data
Nominal transfer at 5 V: output voltage to pressure (17 rows)Calculated from the maker's data
| Output (V) | Pressure (kPa) | Pressure (psi) |
|---|---|---|
| 0.5 | 0 | 0 |
| 0.75 | 43.1 | 6.25 |
| 1 | 86.2 | 12.5 |
| 1.25 | 129.3 | 18.75 |
| 1.5 | 172.4 | 25 |
| 1.75 | 215.5 | 31.25 |
| 2 | 258.6 | 37.5 |
| 2.25 | 301.6 | 43.75 |
| 2.5 | 344.7 | 50 |
| 2.75 | 387.8 | 56.25 |
| 3 | 430.9 | 62.5 |
| 3.25 | 474 | 68.75 |
| 3.5 | 517.1 | 75 |
| 3.75 | 560.2 | 81.25 |
| 4 | 603.3 | 87.5 |
| 4.25 | 646.4 | 93.75 |
| 4.5 | 689.5 | 100 |
Interpolated between the maker's published points; nominal values with no tolerance band.
Native support across ECUs
| ECU platform | Status | How to set it up | Source |
|---|---|---|---|
| GAINS ECU2Concept | Configurable (generic input) | Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware. | Medium3 |
| Haltech (Elite / Nexus) | Configurable (generic input) | One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function. | Medium5 |
| Link (G4X) | Configurable (generic input) | Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered. | Medium6 |
| MoTeC (M1) | Configurable (generic input) | Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor. | Medium7 |
| ECUMaster (EMU Black) | Configurable (generic input) | One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure. | Medium8 |
| AEM (Infinity) | Configurable (generic input) | Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered. | Medium9 |
| MaxxECU | Configurable (generic input) | Extra 0-5 V input on the RACE. The public page does not describe calibration entry. | Medium10 |
| Holley (Terminator X / EFI) | Unverified | Not checked: we cite only public product pages, and none for Holley covers this sensor. | No public source |
Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.
Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.
CAD and drawings
- Parts cataloguePX3 Series product nomenclature (PDF, hosted by RS Components)2Download from HoneywellNo login at last check; the maker may change this
We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.
Wiring and installation
It is a ratiometric 0.5-4.5 V sensor, so it takes 5 V reference, sensor ground and a signal to an analog input with no pull-up. Confirm which Metri-Pack cavity carries which function from Honeywell's installation sheet before wiring.Medium21
Fuel and hot oil are fire hazards. Use a thread sealant compatible with the medium on the NPT port, keep the transducer off direct engine vibration where you can, and leak-check under pressure before running.Medium1
Failure modes and checks
Likely cause Blocked port or a tee fitting not open to the gallery
Check Check the fitting and port; 0.5 V is the zero-pressure output.Medium2
Test it with a multimeter
- Key on, engine off, system depressurised: back-probe signal to sensor ground and expect about 0.5 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data
Frequently asked
What does PX3AN1BH100PSAAX mean?
Honeywell's code reads: PX3 series, A = Metri-Pack 150 connector, N1 = 1/4-18 NPT port, B = brass, H = HNBR seal (-30 to 135 °C), 100P = 100 psi, S = sealed gage, AA = 0.5-4.5 V ratiometric, X = no special option.2
Can I use a Honeywell PX3 for oil pressure?
Yes, the 100 psi sealed-gage version suits typical engine oil pressure. Its HNBR seal is rated -30 to 135 °C; check the seal's media compatibility table in Honeywell's data sheet for your oil and fuel.Medium2
What is the transfer function of a 100 psi 0.5-4.5 V sensor?
Nominally 0.5 V at 0 psi rising 40 mV per psi to 4.5 V at 100 psi, with a 5 V supply. Because the output is ratiometric, a low reference voltage lowers the reading in proportion.Medium2
Related
Use it with GAINS
Honeywell PX3 100 psi sealed-gage pressure transducer (PX3AN1BH100PSAAX) on GAINS hardware
GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34
Concept Pre-release hardware. Pin assignments come from the current design documents and may change.
Sources
10 sources
- Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
- Heavy Duty Pressure Transducers PX3 Series: product nomenclature (008309-1-EN IL50, March 2016) · Honeywell International Inc. (hosted by RS Components) · vendor-doc · retrieved 2026-11-04
- internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
- internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
- Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
- G4X FuryX product page · Link Engine Management · vendor-doc · retrieved 2026-10-27
- M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
- EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
- Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
- MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04