Honeywell · Analog 0-5 V (ratiometric)

Honeywell PX3 100 psi sealed-gage pressure transducer (PX3AN1BH100PSAAX)

Honeywell PX3AN1BH100PSAAX

PX3AN1BH100PSAAX is a Honeywell PX3 heavy-duty pressure transducer: 0-100 psi (6.9 bar) sealed gage, 0.5-4.5 V ratiometric output, 1/4-18 NPT brass port, HNBR seal rated -30 to 135 °C and a Metri-Pack 150 connector. Its 100 psi span fits typical engine oil and port-injection fuel pressure. Honeywell's nomenclature defines each code; the pin assignment is not in the document we archived.2

Key specifications

Measures: Sealed-gage pressure, 0-100 psi (0-6.9 bar). Output: Analog 0-5 V (ratiometric).

Range / reference0-100 psi, sealed gage6.9 barHoneywell offers sealed gage only from 8 bar / 100 psi up; lower ranges are absolute.Sourced2
Output0.5-4.5V ratiometriccode AASourced2
Port1/4-18 NPT male, brasscodes N1, BSourced2
SealHNBR, -30 to 135 °C (-22 to 275 °F) (code H)Sourced2
ConnectorMetri-Pack 150, standard UL V-0 (code A)Sourced2
Supply, accuracy and overpressureUnverifiedNot in the nomenclature sheet we archived; read them from Honeywell's full PX3 data sheet.Researched, unverified
Pin assignmentUnverifiedNot in the archived Honeywell document; confirm against Honeywell's PX3 installation instructions before wiring.Researched, unverified
Part numberMakerNote
PX3AN1BH100PSAAXHoneywellMetri-Pack 150, 1/4-18 NPT, brass, HNBR seal, 100 psi, sealed gage, 0.5-4.5 V ratiometric (decoded from Honeywell's nomenclature)2

Pinout and connector

No pinout is shown: the maker or OEM does not publish one in a document we could cite. Identify pins with a meter before wiring.

Connector: Aptiv (Delphi) Metri-Pack 150, 3-way; mating part Honeywell cable 3685301 (1 m) or 3685302 (3 m)2 Connector library

Terminals and seals: Not listed in the nomenclature sheet.

Transfer function and calibration data

Nominal transfer at 5 VMedium2

Ua = 0.5 V + 0.04 V/psi × p (nominal, at 5 V supply)

0.51.52.53.54.50255075100Pressure (psi)Output (V)

Points computed from Honeywell's 0.5-4.5 V output code across the 0-100 psi range; accuracy limits not shown.

Show the 5 data points
Pressure (psi)Output (V)
00.5
251.5
502.5
753.5
1004.5

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.5–4.5 V → 0–689 kPa (maker: Ua = 0.5 V + 0.04 V/psi × p (nominal, at 5 V supply))2Calculated from the maker's data

Worked conversion

  • At 2.5 V the maker's transfer line gives 345 kPa (50 psi).2Calculated from the maker's data
Nominal transfer at 5 V: output voltage to pressure (17 rows)Calculated from the maker's data
Output (V)Pressure (kPa)Pressure (psi)
0.500
0.7543.16.25
186.212.5
1.25129.318.75
1.5172.425
1.75215.531.25
2258.637.5
2.25301.643.75
2.5344.750
2.75387.856.25
3430.962.5
3.2547468.75
3.5517.175
3.75560.281.25
4603.387.5
4.25646.493.75
4.5689.5100

Interpolated between the maker's published points; nominal values with no tolerance band.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium3
Haltech (Elite / Nexus)Configurable (generic input)One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function.Medium5
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium6
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor.Medium7
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure.Medium8
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium9
MaxxECUConfigurable (generic input)Extra 0-5 V input on the RACE. The public page does not describe calibration entry.Medium10
Holley (Terminator X / EFI)UnverifiedNot checked: we cite only public product pages, and none for Holley covers this sensor.No public source

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

  • Parts cataloguePX3 Series product nomenclature (PDF, hosted by RS Components)2Download from HoneywellNo login at last check; the maker may change this

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

It is a ratiometric 0.5-4.5 V sensor, so it takes 5 V reference, sensor ground and a signal to an analog input with no pull-up. Confirm which Metri-Pack cavity carries which function from Honeywell's installation sheet before wiring.Medium21

Fuel and hot oil are fire hazards. Use a thread sealant compatible with the medium on the NPT port, keep the transducer off direct engine vibration where you can, and leak-check under pressure before running.Medium1

Failure modes and checks

Reads 0.5 V with oil pressure present

Likely cause Blocked port or a tee fitting not open to the gallery

Check Check the fitting and port; 0.5 V is the zero-pressure output.Medium2

Pressure reads a few psi off at idle on a hot engine versus a mechanical gauge

Likely cause Sealed gage reference: the sensor compares to a sealed internal reference, not local atmosphere

Check Check against a calibrated gauge; altitude and weather shift a sealed-gage reading slightly.Low21

Test it with a multimeter

  • Key on, engine off, system depressurised: back-probe signal to sensor ground and expect about 0.5 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data

Frequently asked

What does PX3AN1BH100PSAAX mean?

Honeywell's code reads: PX3 series, A = Metri-Pack 150 connector, N1 = 1/4-18 NPT port, B = brass, H = HNBR seal (-30 to 135 °C), 100P = 100 psi, S = sealed gage, AA = 0.5-4.5 V ratiometric, X = no special option.2

Can I use a Honeywell PX3 for oil pressure?

Yes, the 100 psi sealed-gage version suits typical engine oil pressure. Its HNBR seal is rated -30 to 135 °C; check the seal's media compatibility table in Honeywell's data sheet for your oil and fuel.Medium2

What is the transfer function of a 100 psi 0.5-4.5 V sensor?

Nominally 0.5 V at 0 psi rising 40 mV per psi to 4.5 V at 100 psi, with a 5 V supply. Because the output is ratiometric, a low reference voltage lowers the reading in proportion.Medium2

Related

Use it with GAINS

Honeywell PX3 100 psi sealed-gage pressure transducer (PX3AN1BH100PSAAX) on GAINS hardware

ECU2AVI (0-5 V, pull-up off)

Pins
On the ECU2 pin map
Pull-up
Off
Shielding
Not needed

Any free analog input with its pull-up off; 5 V from pin 28, ground to pin 29.Medium3

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

10 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
  2. Heavy Duty Pressure Transducers PX3 Series: product nomenclature (008309-1-EN IL50, March 2016) · Honeywell International Inc. (hosted by RS Components) · vendor-doc · retrieved 2026-11-04
  3. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  4. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  5. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
  6. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  7. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
  8. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  9. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04