Bosch · NTC thermistor

Bosch NTC M12 temperature sensor

Bosch 0 280 130 026

The Bosch NTC M12 (0 280 130 026) is a fluid temperature thermistor for coolant, oil or fuel from -40 to 130 °C. It reads 2.5 kΩ ± 5 % at 20 °C and 187 Ω at 100 °C, threads in M12x1.5 at 25 N·m and uses a 2-pole Jetronic connector. Bosch suggests a 1 or 3 kΩ pull-up at the ECU.1

Key specifications

Measures: Temperature of coolant, oil or fuel. Output: NTC thermistor.

Range-40 to 130°CSourced1
Nominal resistance2.5 kΩ ± 5 % at 20 °CSourced1
Accuracy
  • ± 1.4 °C at 25 °C
  • ± 3.4 °C at 100 °C
Sourced1
Response< 15stau 63, still waterSourced1
Thread / torque
  • M12x1.5, 19 mm, 25 N·m
  • Sealing not included
Sourced1
Fuel compatibilityE85 / M22Sourced1
Part numberMakerNote
0 280 130 026Bosch1

Pinout and connector

12Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
1SIG+Temperature input (pull-up on)—
2SIG−Sensor groundReturn to sensor ground, not chassis

Element pins; the NTC has no polarity.1 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Jetronic 2-pole; mating part D261.205.288-011 Connector library

Terminals and seals: Not listed: the Bosch data sheet gives the mating housing only, not contact or seal part numbers.

Transfer function and calibration data

Resistance vs temperature1
1001,00010,000-402.54587.5130Temperature (°C)Resistance (Ω), log scale
Show the 18 data points
Temperature (°C)Resistance (Ω)
-4045,313
-3026,114
-2015,462
-109,397
05,896
103,792
202,500
301,707
401,175
50834
60596
70436
80323
90243
100187
110144
120113
13089

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • NTC: 45,313 Ω at -40 °C falling to 89 Ω at 130 °C1
  • Steinhart-Hart fit through -40 °C, 50 °C, 130 °C: A = 1.3095e-3, B = 2.5726e-4, C = 1.7969e-7 (largest error against the maker's table 0.25 °C).1Calculated from the maker's data

Worked conversion

  • At 20 °C the element is 2,500 Ω; with a 1 kΩ pull-up to 5 V the ECU sees 5 × 2,500 / (2,500 + 1,000) = 3.571 V.11Calculated from the maker's data
Resistance vs temperature: resistance and ECU input voltage (18 rows)Calculated from the maker's data
Temperature (°C)Resistance (Ω)V at 1 kΩ pull-up to 5 VV at 3 kΩ pull-up to 5 V
-40453134.8924.69
-30261144.8164.485
-20154624.6964.188
-1093974.5193.79
058964.2753.314
1037923.9572.792
2025003.5712.273
3017073.1531.813
4011752.7011.407
508342.2741.088
605961.8670.829
704361.5180.634
803231.2210.486
902430.9770.375
1001870.7880.293
1101440.6290.229
1201130.5080.181
130890.4090.144

Resistance from the maker's table; voltages calculated for the maker-recommended pull-ups.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)AVI with the switchable pull-up on (AVI5, pin 14, is the default coolant input). Concept hardware.Medium2
Haltech (Elite / Nexus)Configurable (generic input)AVI with its software-selectable 1 kΩ pull-up to 5 V switched on; enter the maker's resistance table.Medium6
Link (G4X)Configurable (generic input)Temperature input with the selectable pull-up switched on (4 on the FuryX). Pull-up value not stated for G4X.7
MoTeC (M1)Preset listedMoTeC's sensor page says to use the predefined M1 calibration for Bosch 0 280 130 026 (status only; its table is not reproduced here).8
ECUMaster (EMU Black)Configurable (generic input)Temperature sensor input (IAT, CLT and oil temperature are listed). Pull-up value not stated publicly.Medium9
AEM (Infinity)Configurable (generic input)Analog temperature input (2.49 kΩ pull-up to 5 V per the Series 5 spec).10
MaxxECUConfigurable (generic input)Temperature input (2 extra on the RACE). Pull-up value not on the public pages.Medium11
Holley (Terminator X / EFI)Configurable (generic input)Thermistor 'T' input for two-wire temperature sensors. Pull-up value not stated.12

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Two wires, non-polarised: one to an analog input with the pull-up on, one to sensor ground. Any mounting orientation is allowed.1

Failure modes and checks

Reads cold when hot

Likely cause Open circuit or corroded Jetronic contacts

Check Measure resistance at the plug against the table.Medium1

Weeping thread

Likely cause No sealing washer (not included)

Check Fit a suitable sealing washer or thread sealant for the port.Medium1

Test it with a multimeter

  • Unplugged, measure resistance across the two element pins: about 2,500 Ω at 20 °C, falling as it warms (compare with the table).1Calculated from the maker's data

Frequently asked

What is the resistance of the Bosch 0 280 130 026?

2,500 Ω at 20 °C, 5,896 Ω at 0 °C and 187 Ω at 100 °C, per Bosch's table.1

What pull-up resistor suits the Bosch NTC M12?

Bosch suggests 1 or 3 kΩ. Enter the same value in the ECU or the thermistor calculator so the voltage converts to the right temperature.1

Related

Use it with GAINS

Bosch NTC M12 temperature sensor on GAINS hardware

ECU2AVI (thermistor, pull-up on)

Pins
On the ECU2 pin map
Pull-up
On
Shielding
Not needed

Any free analog input with its pull-up switched on.Medium2

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.23

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

12 sources
  1. Temperature Sensor NTC M12 data sheet 70101387 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-10-27
  2. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  3. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  4. NTC M12 product page · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
  5. Nexus R3 wiring diagram (HT-193000_WD) · Haltech · vendor-doc · retrieved 2026-10-27
  6. Water Temperature Sensor product page (#55001) · MoTeC · vendor-doc · retrieved 2026-10-27
  7. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-10-27
  8. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  9. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-10-27
  10. HP / Dominator EFI wiring manual 199R10555 · Holley · vendor-doc · retrieved 2026-10-27

Not yet indexed: fewer than 3 FAQs.