Intercooler efficiency calculator

Intercooler efficiency = (charge temperature in − charge temperature out) ÷ (charge temperature in − ambient temperature). Log temperatures before and after the core plus ambient to see how much of the possible cooling the intercooler delivers.

°F

Measure in the pipe just before the core, or estimate it with the compressor outlet temperature calculator.

°F
°F

Outside air for air-to-air; coolant entering the core for air-to-water.

Result

Intercooler efficiency82.4 %
Temperature drop across core140.0 °F
Maximum possible drop (to ambient)170.0 °F
Charge density gain from cooling24.6 %at equal pressure; pressure drop across the core reduces it

Planning estimate from the formula below, not a measurement.

How it works

The formula, the method step by step, then a worked example.

η_IC = (T_in − T_out) ÷ (T_in − T_amb);  density gain = T_in(abs) ÷ T_out(abs) − 1
  1. The most heat any intercooler could remove would cool the charge all the way to the cooling medium's temperature (T_in − T_amb).
  2. Efficiency (heat-exchanger effectiveness) is the share of that maximum it actually removes (T_in − T_out).
  3. At the same pressure, gas density is inversely proportional to absolute temperature, so cooler charge is denser.

Worked example

Inputs

Charge temperature into intercooler (compressor outlet)
250 °F
Charge temperature out of intercooler
110 °F
Ambient (cooling medium) temperature
80 °F

Result

Intercooler efficiency82.4%
Temperature drop across core140.0°F
Maximum possible drop (to ambient)170.0°F
Charge density gain from cooling24.6%

Assumptions and limits

  • Effectiveness with the charge air as the limiting (smaller heat-capacity) stream, as in the standard effectiveness-NTU treatment.
  • Steady state: during short pulls the core's own thermal mass makes efficiency read higher than it would in a long pull.
  • Ignores the pressure drop across the core, which lowers density; measure pressure before and after the core too.

Related terms

Frequently asked

How do you calculate intercooler efficiency?

Divide the temperature drop across the intercooler by the drop that would be possible if it cooled the charge all the way to ambient: (T in − T out) ÷ (T in − ambient). For example, 250 °F in, 110 °F out and 80 °F ambient gives 140 ÷ 170, or about 82%.

What is a good intercooler efficiency?

Well-sized air-to-air intercoolers commonly log roughly 70-85% during a pull, and air-to-water systems can read higher at first while the coolant is cold, then fall as it heats up. Compare runs of the same length, because short pulls flatter any intercooler.

Why does my intercooler efficiency read over 100%?

The outlet sensor reads below ambient, which a passive intercooler cannot do. Usually the ambient sensor is heat soaked, the outlet sensor is slow or badly placed, or a water spray or ice-cooled air-to-water system is cooling below outside air.

Does a bigger intercooler always help?

It usually lowers charge temperature, but a larger core can add pressure drop and volume. Pressure lost across the core must be made up with more boost, which heats the charge again, so check pressure before and after the core as well as temperature.

Answers draw on the sources below.

Sources

  1. Fundamentals of Heat and Mass Transfer (7th ed.), ch. 11: heat exchangers, effectiveness-NTU method · Bergman, Lavine, Incropera, DeWitt, Wiley, 2011
  2. Internal Combustion Engine Fundamentals (2nd ed.) · J. B. Heywood, McGraw-Hill, 2018
  3. Turbo Tech 103: Expert compressor matching · Garrett Motion

Spot an error? Tell us.