MAP sensor voltage to pressure calculator
A linear MAP sensor follows pressure = offset + slope × voltage. Pick a 1-, 2.5-, 3- or 4-bar data-sheet sensor or enter two calibration points to convert voltage to kPa and back, and get the slope and offset your ECU asks for.
Result
Planning estimate from the formula below, not a measurement.
How it works
The formula, the method step by step, then a worked example.
P = P₁ + (V − V₁) × (P₂ − P₁) ÷ (V₂ − V₁); data-sheet form: V_out = V_s × (k × P(kPa) − c)
- Two known (voltage, pressure) points define a straight line.
- Slope is the pressure change per volt; offset is the pressure the line reaches at 0 V. Many ECUs ask for exactly these two numbers.
- For the listed sensors, the two points are the ends of the rated range from the maker's nominal transfer function at your supply voltage.
Worked example
Inputs
- Sensor
- 3
- Supply voltage
- 5 V
- Custom point 1 voltage
- 0.5 V
- Custom point 1 pressure (absolute)
- 1.45 psi
- Custom point 2 voltage
- 4.5 V
- Custom point 2 pressure (absolute)
- 43.51 psi
- Sensor voltage to convert
- 2.5 V
- Pressure to convert (absolute)
- 14.7 psi
Result
Assumptions and limits
- Linear, ratiometric sensors only; nominal transfer function without the data sheet's error band (typically ±1.5% to ±2.5% of span).
- Absolute pressure; subtract barometric pressure for boost (see the boost pressure converter).
- Example sensors are named for their published transfer functions. OEM sensors with the same bar rating can have different calibrations.
Related terms
Frequently asked
How do I convert MAP sensor voltage to kPa?
Use the sensor's straight line: pressure = offset + slope × voltage. For the MPX4250A at 5 V, kPa = (V ÷ 5 + 0.04) ÷ 0.004, so 2.5 V is 135 kPa. Other sensors need their own slope and offset from the data sheet.
What voltage does a MAP sensor read at atmospheric pressure?
It depends on the sensor's range. At 101.3 kPa and 5 V supply, a 115 kPa sensor (MPX4115A) reads about 4.08 V, a 250 kPa sensor about 1.83 V, a 300 kPa sensor about 1.59 V and a 400 kPa sensor about 1.18 V.
What is the difference between a 2-bar and 3-bar MAP sensor?
The rating is roughly the highest absolute pressure it can read. A 3-bar sensor covers about 300 kPa absolute, around 29 psi of boost at sea level, but spreads it over the same 0-5 V, so each volt means more kPa and resolution is coarser.
Answers draw on the sources below.
Sources
- MPX4115A, MPX4250A, MPXH6400A integrated pressure sensor data sheets (nominal transfer functions) · NXP Semiconductors (formerly Freescale/Motorola)
- MPXH6300A integrated pressure sensor data sheet · NXP Semiconductors, hosted by STMicroelectronics
- Automotive Handbook · Robert Bosch GmbH
Spot an error? Tell us.