Bosch · Analog 0-5 V (ratiometric)

Bosch PS-AS 3 bar absolute air pressure sensor (0 281 002 996)

Bosch 0 281 002 996

Bosch 0 281 002 996 is the PS-AS 3-bar absolute pressure sensor: 0.2-3 bar (2.9-43.5 psi), so about 2 bar (29 psi) of boost at sea level. It needs 5 V and outputs 0.4-4.65 V ratiometric at 1,518 mV per bar with a 96 mV offset. Pins: 1 supply, 2 ground, 3 signal. It has no temperature element.2

Key specifications

Measures: Absolute air pressure, 0.2-3 bar (2.9-43.5 psi). Output: Analog 0-5 V (ratiometric).

Range
  • 0.2-3 bar absolute2.9-43.5 psi
  • 5 bar maximum72.5 psi
Sourced2
Output0.4-4.65 V ratiometric at 5 V supplySourced2
Sensitivity / offset
  • 1,518 mV/bar
  • 96 mV
Sourced2
Tolerance± 0.030 bar (± 1.07 % FS) at 5 V, compensated 10-85 °CSourced2
Supply4.75-5.25V, 9 mA16 V maxSourced2
Response time1msT10/90Sourced2
Mounting
  • M6 screw
  • 12.05 mm fitting with 7.59 x 2.62 mm O-ring
  • 21 g
Sourced2
Part numberMakerNote
0 281 002 996BoschPrinted 0281.002.996 on the data sheet2

Pinout and connector

123Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
1Supply (US, 5 V)+5 V sensor reference—
2GroundSensor groundReturn to sensor ground, not chassis
3Pressure signalAnalog voltage input (pull-up off)—

Pin functions as Bosch publishes them; the drawing is a schematic in pin order, not the connector's true cavity layout.2 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Compact 1.1a, 3-pole, coding 1 (RB-COMP 1.1a/3P/Kod.1); mating part D261.205.366-012 Connector library

Terminals and seals: Not listed: the data sheet gives the mating housing only.

Transfer function and calibration data

Pressure transfer at 5 V2

Ua = 1.518 V/bar × p + 0.096 V (at Us = 5 V)

0.41.4622.5253.5874.650.20.91.62.33Absolute pressure (bar)Output (V)

Points computed from Bosch's sensitivity and offset.

Show the 4 data points
Absolute pressure (bar)Output (V)
0.20.4
11.614
23.132
34.65

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.4–4.65 V → 20–300 kPa absolute (maker: Ua = 1.518 V/bar × p + 0.096 V (at Us = 5 V))2Calculated from the maker's data

Worked conversion

  • At 2.53 V the maker's transfer line gives 160 kPa absolute (23.3 psia).2Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (9 rows)Calculated from the maker's data
Output (V)Pressure (kPa absolute)Pressure (psia)
0.526.63.86
159.58.64
1.592.513.41
2125.418.19
2.5158.422.97
3191.327.75
3.5224.232.52
4257.237.3
4.5290.142.08

Interpolated between the maker's published points; nominal values with no tolerance band.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium4
Haltech (Elite / Nexus)Configurable (generic input)One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function.Medium6
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium7
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor.Medium8
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure.Medium9
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium10
MaxxECUConfigurable (generic input)Extra 0-5 V input on the RACE. The public page does not describe calibration entry.Medium11
Holley (Terminator X / EFI)UnverifiedNot checked: we cite only public product pages, and none for Holley covers this sensor.No public source

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Three wires: 5 V reference to pin 1, sensor ground to pin 2, pin 3 to an analog input with the pull-up off. Bosch recommends a 2 ms RC filter at the input and a mounting angle within ±60° of vertical.2

Failure modes and checks

Reads about 1 bar with the engine running at idle

Likely cause Sensor port open to atmosphere instead of the manifold, or hose off

Check Compare key-on, engine-off reading with local barometric pressure, then check the reading drops at idle.Medium21

Noisy or jumping pressure trace

Likely cause No input filtering at the ECU

Check Bosch recommends an RC low-pass filter with a time constant of about 2 ms on the ECU input.2

Offset drifts after cold or wet running

Likely cause Condensate in the port

Check Mount the port facing down, within ±60° of vertical as Bosch specifies.2

Test it with a multimeter

  • Key on, engine off, port open to air: back-probe signal to sensor ground and expect about 1.63 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data

Frequently asked

What is the pinout of the Bosch 0 281 002 996?

Pin 1 is the 5 V supply, pin 2 ground and pin 3 the pressure signal, on a 3-pole Bosch Compact connector (mating housing D261.205.366-01).2

How does the PS-AS differ from the PST 3?

Both read 0.2-3 bar absolute with the same 1,518 mV per bar slope. The PST 3 (0 261 230 280) adds an NTC air temperature element on a fourth pin; the PS-AS is pressure only on three pins.23

What voltage does a Bosch 3 bar MAP sensor give at atmosphere?

About 1.61 V at 1 bar absolute with a 5 V supply, from Bosch's 1,518 mV per bar and 96 mV offset. Actual ambient pressure varies with weather and altitude, so expect some spread.Medium2

Related

Use it with GAINS

Bosch PS-AS 3 bar absolute air pressure sensor (0 281 002 996) on GAINS hardware

ECU2AVI (0-5 V, pull-up off)

Pins
On the ECU2 pin map
Pull-up
Off
Shielding
Not needed

Any free analog input with its pull-up off; 5 V from pin 28, ground to pin 29.Medium4

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.45

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

11 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
  2. Pressure Sensor Air PS-AS data sheet 52373387 (27 Jan 2026) · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-11-04
  3. Bosch Motorsport print catalog 2026 (data as of April 2026), PST 3 pages 257-258 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-11-04
  4. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  5. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  6. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
  7. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  8. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
  9. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  10. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04