Bosch · Analog 0-5 V (ratiometric)

Bosch PST 3 3-bar TMAP sensor (0 261 230 280)

Bosch 0 261 230 280

Bosch 0 261 230 280 is the PST 3 combined pressure and temperature (TMAP) sensor: 0.2-3 bar (2.9-43.5 psi) absolute plus an NTC air temperature element for -40 to 130 °C. Pressure is ratiometric 0.4-4.65 V at 1,518 mV per bar. Pins: 1 ground, 2 temperature, 3 supply, 4 pressure, on a Bosch Compact 4-pole connector.2

Key specifications

Measures: Absolute intake air pressure (0.2-3 bar) and air temperature (-40 to 130 °C). Output: Analog 0-5 V (ratiometric).

Pressure range
  • 0.2-3 bar absolute2.9-43.5 psi
  • 5 bar maximum72.5 psi
Sourced2
Temperature range-40 to 130°C-40 to 266 °FSourced2
Output0.4-4.65 V ratiometric at 5 V supplySourced2
Sensitivity / offset
  • 1,518 mV/bar
  • 96.43 mV
Sourced2
Tolerance± 0.030 bar (± 1.07 % FS) at 5 VSourced2
NTC at 25 °C2,056ΩSourced2
Supply4.75-5.25V, 9 mA16 V maxSourced2
Mounting
  • M6 screw
  • 12.05 mm fitting with 7.59 x 2.62 mm O-ring
  • 24 g
Sourced2
Temperature pull-upUnverifiedThe catalog page lists the NTC table but no recommended pull-up value.Researched, unverified
Part numberMakerNote
0 261 230 280BoschPrinted 0261.230.280 in the Bosch Motorsport catalog2

Pinout and connector

1234Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
1GroundSensor groundReturn to sensor ground, not chassis
2Temperature signal (NTC)Temperature input (pull-up on)—
3Supply (5 V)+5 V sensor reference—
4Pressure signalAnalog voltage input (pull-up off)—

Pin functions as Bosch publishes them; the drawing is a schematic in pin order.2 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Compact, 4-pole; mating part D261.205.360-012 Connector library

Terminals and seals: Not listed: the catalog gives the mating housing only.

Transfer function and calibration data

Pressure transfer at 5 V2

Ua = 1.518 V/bar × p + 0.0964 V (at Us = 5 V)

0.41.4622.5253.5874.650.20.91.62.33Absolute pressure (bar)Output (V)

Points computed from Bosch's sensitivity and offset.

Show the 4 data points
Absolute pressure (bar)Output (V)
0.20.4
11.614
23.132
34.65
Temperature sensor (NTC)2
1001,00010,000-402.54587.5130Temperature (°C)Resistance (Ω), log scale
Show the 19 data points
Temperature (°C)Resistance (Ω)
-4045,303
-3026,108
-2015,458
-109,395
05,895
103,791
202,499
252,056
301,706
401,174
50833.8
60595.4
70435.6
80322.5
90243.1
100186.6
110144.2
120112.7
13089.28

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.4–4.65 V → 20–300 kPa absolute (maker: Ua = 1.518 V/bar × p + 0.0964 V (at Us = 5 V))2Calculated from the maker's data
  • NTC: 45,303 Ω at -40 °C falling to 89.3 Ω at 130 °C2
  • Steinhart-Hart fit through -40 °C, 40 °C, 130 °C: A = 1.2991e-3, B = 2.5963e-4, C = 1.6755e-7 (largest error against the maker's table 0.23 °C).2Calculated from the maker's data

Worked conversion

  • At 2.53 V the maker's transfer line gives 160 kPa absolute (23.3 psia).2Calculated from the maker's data
  • At 25 °C the element is 2,056 Ω; with a 1 kΩ pull-up to 5 V the ECU sees 5 × 2,056 / (2,056 + 1,000) = 3.364 V.2Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (9 rows)Calculated from the maker's data
Output (V)Pressure (kPa absolute)Pressure (psia)
0.526.63.86
159.58.64
1.592.513.41
2125.418.19
2.5158.422.97
3191.327.75
3.5224.232.52
4257.237.3
4.5290.142.08

Interpolated between the maker's published points; nominal values with no tolerance band.

Temperature sensor (NTC): resistance and ECU input voltage (19 rows)Calculated from the maker's data
Temperature (°C)Resistance (Ω)V at 1 kΩ pull-up to 5 VV at 2.2 kΩ pull-up to 5 V
-40453034.8924.768
-30261084.8164.611
-20154584.6964.377
-1093954.5194.051
058954.2753.641
1037913.9563.164
2024993.5712.659
2520563.3642.415
3017063.1522.184
4011742.71.74
50833.82.2731.374
60595.41.8661.065
70435.61.5170.826
80322.51.2190.639
90243.10.9780.498
100186.60.7860.391
110144.20.630.308
120112.70.5060.244
13089.280.410.195

Resistance from the maker's table. The maker does not state a pull-up; 1 kΩ and 2.2 kΩ are example values: use your ECU's actual pull-up.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium3
Haltech (Elite / Nexus)Configurable (generic input)One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function.Medium5
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium6
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor.Medium7
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure.Medium8
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium9
MaxxECUConfigurable (generic input)Extra 0-5 V input on the RACE. The public page does not describe calibration entry.Medium10
Holley (Terminator X / EFI)UnverifiedNot checked: we cite only public product pages, and none for Holley covers this sensor.No public source

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

  • Parts catalogueBosch Motorsport print catalog 2026 (PST 3 on pages 257-258)2Download from Bosch MotorsportNo login at last check; the maker may change this

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Four wires: ground to pin 1, 5 V reference to pin 3, pressure (pin 4) to an analog input with the pull-up off and temperature (pin 2) to an analog input with the pull-up on. Enter Bosch's NTC table against your ECU's pull-up value.Medium2

Bosch recommends a 2 ms RC filter at the pressure input, engine oil rather than silicone grease on the O-ring, and a mounting angle within ±60° of vertical.2

Failure modes and checks

IAT reads far too hot or cold

Likely cause Temperature pin on an input with the pull-up off, or the wrong table

Check Enable the pull-up on the temperature input and enter Bosch's resistance table; 25 °C should read about 2,056 Ω at the sensor.Medium2

Pressure and temperature swapped in the log

Likely cause Pins 2 and 4 crossed

Check Check pin 4 carries the pressure signal and pin 2 the NTC.2

Offset drifts after wet running

Likely cause Condensate in the port

Check Mount the port facing down, within ±60° of vertical.2

Test it with a multimeter

  • Key on, engine off, port open to air: back-probe signal to sensor ground and expect about 1.63 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data
  • Unplugged, measure resistance across the two element pins: about 2,056 Ω at 25 °C, falling as it warms (compare with the table).2Calculated from the maker's data

Frequently asked

What is the pinout of the Bosch PST 3?

Pin 1 ground, pin 2 temperature signal, pin 3 5 V supply and pin 4 pressure signal, on a Bosch Compact 4-pole connector with mating housing D261.205.360-01.2

What is the NTC resistance of the Bosch PST 3?

Bosch lists 2,056 Ω at 25 °C, 5,895 Ω at 0 °C and 186.6 Ω at 100 °C, with a full table from -40 to 130 °C. Enter that table in the ECU against its pull-up value.2

How much boost can the PST 3 read?

About 2 bar (29 psi) of boost at sea level, since its range ends at 3 bar absolute and atmosphere takes roughly 1 bar of it.Medium21

Related

Use it with GAINS

Bosch PST 3 3-bar TMAP sensor (0 261 230 280) on GAINS hardware

ECU2AVI pressure (pull-up off) + AVI temperature (pull-up on)

Pins
On the ECU2 pin map
Pull-up
To be confirmed
Shielding
Not needed

Two analog inputs: pressure with the pull-up off, temperature with it on.Medium3

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

10 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
  2. Bosch Motorsport print catalog 2026 (data as of April 2026), PST 3 pages 257-258 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-11-04
  3. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  4. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  5. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
  6. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  7. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
  8. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  9. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04