Bosch · Analog 0-5 V (ratiometric)
Bosch PST 3 3-bar TMAP sensor (0 261 230 280)
Bosch 0 261 230 280 is the PST 3 combined pressure and temperature (TMAP) sensor: 0.2-3 bar (2.9-43.5 psi) absolute plus an NTC air temperature element for -40 to 130 °C. Pressure is ratiometric 0.4-4.65 V at 1,518 mV per bar. Pins: 1 ground, 2 temperature, 3 supply, 4 pressure, on a Bosch Compact 4-pole connector.2
Key specifications
Measures: Absolute intake air pressure (0.2-3 bar) and air temperature (-40 to 130 °C). Output: Analog 0-5 V (ratiometric).
| Part number | Maker | Note |
|---|---|---|
| 0 261 230 280 | Bosch | Printed 0261.230.280 in the Bosch Motorsport catalog2 |
Pinout and connector
- Supply
- Ground / return
- Signal
- Shield
- Not used / not listed
| Pin | Function (as published) | Typical ECU input | Wire note |
|---|---|---|---|
| 1 | Ground | Sensor ground | Return to sensor ground, not chassis |
| 2 | Temperature signal (NTC) | Temperature input (pull-up on) | — |
| 3 | Supply (5 V) | +5 V sensor reference | — |
| 4 | Pressure signal | Analog voltage input (pull-up off) | — |
Pin functions as Bosch publishes them; the drawing is a schematic in pin order.2 The ECU-input and wire columns are our general guidance, not the maker's.
Connector: Bosch Compact, 4-pole; mating part D261.205.360-012 Connector library
Terminals and seals: Not listed: the catalog gives the mating housing only.
Transfer function and calibration data
Ua = 1.518 V/bar × p + 0.0964 V (at Us = 5 V)
Points computed from Bosch's sensitivity and offset.
Show the 4 data points
| Absolute pressure (bar) | Output (V) |
|---|---|
| 0.2 | 0.4 |
| 1 | 1.614 |
| 2 | 3.132 |
| 3 | 4.65 |
Show the 19 data points
| Temperature (°C) | Resistance (Ω) |
|---|---|
| -40 | 45,303 |
| -30 | 26,108 |
| -20 | 15,458 |
| -10 | 9,395 |
| 0 | 5,895 |
| 10 | 3,791 |
| 20 | 2,499 |
| 25 | 2,056 |
| 30 | 1,706 |
| 40 | 1,174 |
| 50 | 833.8 |
| 60 | 595.4 |
| 70 | 435.6 |
| 80 | 322.5 |
| 90 | 243.1 |
| 100 | 186.6 |
| 110 | 144.2 |
| 120 | 112.7 |
| 130 | 89.28 |
How it's calibrated
ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.
Transfer function
- 0.4–4.65 V → 20–300 kPa absolute (maker: Ua = 1.518 V/bar × p + 0.0964 V (at Us = 5 V))2Calculated from the maker's data
- NTC: 45,303 Ω at -40 °C falling to 89.3 Ω at 130 °C2
- Steinhart-Hart fit through -40 °C, 40 °C, 130 °C: A = 1.2991e-3, B = 2.5963e-4, C = 1.6755e-7 (largest error against the maker's table 0.23 °C).2Calculated from the maker's data
Worked conversion
- At 2.53 V the maker's transfer line gives 160 kPa absolute (23.3 psia).2Calculated from the maker's data
- At 25 °C the element is 2,056 Ω; with a 1 kΩ pull-up to 5 V the ECU sees 5 × 2,056 / (2,056 + 1,000) = 3.364 V.2Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (9 rows)Calculated from the maker's data
| Output (V) | Pressure (kPa absolute) | Pressure (psia) |
|---|---|---|
| 0.5 | 26.6 | 3.86 |
| 1 | 59.5 | 8.64 |
| 1.5 | 92.5 | 13.41 |
| 2 | 125.4 | 18.19 |
| 2.5 | 158.4 | 22.97 |
| 3 | 191.3 | 27.75 |
| 3.5 | 224.2 | 32.52 |
| 4 | 257.2 | 37.3 |
| 4.5 | 290.1 | 42.08 |
Interpolated between the maker's published points; nominal values with no tolerance band.
Temperature sensor (NTC): resistance and ECU input voltage (19 rows)Calculated from the maker's data
| Temperature (°C) | Resistance (Ω) | V at 1 kΩ pull-up to 5 V | V at 2.2 kΩ pull-up to 5 V |
|---|---|---|---|
| -40 | 45303 | 4.892 | 4.768 |
| -30 | 26108 | 4.816 | 4.611 |
| -20 | 15458 | 4.696 | 4.377 |
| -10 | 9395 | 4.519 | 4.051 |
| 0 | 5895 | 4.275 | 3.641 |
| 10 | 3791 | 3.956 | 3.164 |
| 20 | 2499 | 3.571 | 2.659 |
| 25 | 2056 | 3.364 | 2.415 |
| 30 | 1706 | 3.152 | 2.184 |
| 40 | 1174 | 2.7 | 1.74 |
| 50 | 833.8 | 2.273 | 1.374 |
| 60 | 595.4 | 1.866 | 1.065 |
| 70 | 435.6 | 1.517 | 0.826 |
| 80 | 322.5 | 1.219 | 0.639 |
| 90 | 243.1 | 0.978 | 0.498 |
| 100 | 186.6 | 0.786 | 0.391 |
| 110 | 144.2 | 0.63 | 0.308 |
| 120 | 112.7 | 0.506 | 0.244 |
| 130 | 89.28 | 0.41 | 0.195 |
Resistance from the maker's table. The maker does not state a pull-up; 1 kΩ and 2.2 kΩ are example values: use your ECU's actual pull-up.
Native support across ECUs
| ECU platform | Status | How to set it up | Source |
|---|---|---|---|
| GAINS ECU2Concept | Configurable (generic input) | Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware. | Medium3 |
| Haltech (Elite / Nexus) | Configurable (generic input) | One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function. | Medium5 |
| Link (G4X) | Configurable (generic input) | Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered. | Medium6 |
| MoTeC (M1) | Configurable (generic input) | Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor. | Medium7 |
| ECUMaster (EMU Black) | Configurable (generic input) | One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure. | Medium8 |
| AEM (Infinity) | Configurable (generic input) | Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered. | Medium9 |
| MaxxECU | Configurable (generic input) | Extra 0-5 V input on the RACE. The public page does not describe calibration entry. | Medium10 |
| Holley (Terminator X / EFI) | Unverified | Not checked: we cite only public product pages, and none for Holley covers this sensor. | No public source |
Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.
Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.
CAD and drawings
- Parts catalogueBosch Motorsport print catalog 2026 (PST 3 on pages 257-258)2Download from Bosch MotorsportNo login at last check; the maker may change this
We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.
Wiring and installation
Four wires: ground to pin 1, 5 V reference to pin 3, pressure (pin 4) to an analog input with the pull-up off and temperature (pin 2) to an analog input with the pull-up on. Enter Bosch's NTC table against your ECU's pull-up value.Medium2
Bosch recommends a 2 ms RC filter at the pressure input, engine oil rather than silicone grease on the O-ring, and a mounting angle within ±60° of vertical.2
Failure modes and checks
Likely cause Temperature pin on an input with the pull-up off, or the wrong table
Check Enable the pull-up on the temperature input and enter Bosch's resistance table; 25 °C should read about 2,056 Ω at the sensor.Medium2
Likely cause Pins 2 and 4 crossed
Check Check pin 4 carries the pressure signal and pin 2 the NTC.2
Likely cause Condensate in the port
Check Mount the port facing down, within ±60° of vertical.2
Test it with a multimeter
- Key on, engine off, port open to air: back-probe signal to sensor ground and expect about 1.63 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data
- Unplugged, measure resistance across the two element pins: about 2,056 Ω at 25 °C, falling as it warms (compare with the table).2Calculated from the maker's data
Frequently asked
What is the pinout of the Bosch PST 3?
Pin 1 ground, pin 2 temperature signal, pin 3 5 V supply and pin 4 pressure signal, on a Bosch Compact 4-pole connector with mating housing D261.205.360-01.2
What is the NTC resistance of the Bosch PST 3?
Bosch lists 2,056 Ω at 25 °C, 5,895 Ω at 0 °C and 186.6 Ω at 100 °C, with a full table from -40 to 130 °C. Enter that table in the ECU against its pull-up value.2
Related
Use it with GAINS
Bosch PST 3 3-bar TMAP sensor (0 261 230 280) on GAINS hardware
GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34
Concept Pre-release hardware. Pin assignments come from the current design documents and may change.
Sources
10 sources
- Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
- Bosch Motorsport print catalog 2026 (data as of April 2026), PST 3 pages 257-258 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-11-04
- internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
- internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
- Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
- G4X FuryX product page · Link Engine Management · vendor-doc · retrieved 2026-10-27
- M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
- EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
- Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
- MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04