Bosch · Analog 0-5 V (ratiometric)

Bosch PST 4 4-bar TMAP sensor

Bosch 0 261 230 423

The Bosch PST 4 (0 261 230 423) is a 4-bar TMAP: absolute pressure from 0.4 to 4 bar plus intake air temperature. Output is ratiometric, 1.143 V per bar with a −71.4 mV offset at 5 V, so 0.4 bar reads 0.386 V and 4 bar reads 4.5 V. The temperature side is an NTC reading 2,056 Ω at 25 °C.1

Key specifications

Measures: Absolute manifold or airbox pressure (0.4-4 bar) and air temperature (-40 to 130 °C). Output: Analog 0-5 V (ratiometric).

Pressure range
  • 0.4-4 bar absolute
  • 6 bar maximum
Sourced1
Output0.386-4.5 V full scale, ratiometric at 5 VSourced1
Sensitivity / offset
  • 1,143 mV/bar
  • −71.43 mV
Sourced1
Tolerance
  • 0.042 bar full scale at 5 V
  • Compensated 10-85 °C
Sourced1
Response time1msT10/90Sourced1
Supply
  • 4.75-5.25 V
  • 16 V max
  • 12 mA
Sourced1
Mounting
  • M6 screw with washer
  • O-ring 7.59 × 2.62 mm
  • Within ±60° of vertical
Sourced1
FuelsDesigned for ROZ95, ROZ98, M15, E22 and diesel enginesSourced1
Part numberMakerNote
0 261 230 423Bosch1

Pinout and connector

1234Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
1GroundSensor groundReturn to sensor ground, not chassis
2Temperature signalTemperature input (pull-up on)—
3Power supply (5 V)+5 V sensor reference—
4Pressure signalAnalog voltage input (pull-up off)—

Pins 2 and 3 read from the Bosch data sheet in a second pass; the same assignment as the PST 1.Medium1 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Compact; mating part D261.205.360-011 Connector library

Terminals and seals: Not listed: the Bosch data sheet gives the mating housing only, not contact or seal part numbers.

Transfer function and calibration data

Pressure transfer at 5 V1

Ua = 1.143 V/bar × p − 0.0714 V (at Us = 5 V)

0.3861.4152.4443.4724.5010.41.32.23.14Absolute pressure (bar)Output (V)

Points computed from Bosch's sensitivity and offset.

Show the 5 data points
Absolute pressure (bar)Output (V)
0.40.386
1.31.414
2.22.443
3.13.472
44.501
Temperature sensor (NTC)1
1001,00010,000-402.54587.5130Temperature (°C)Resistance (Ω), log scale
Show the 19 data points
Temperature (°C)Resistance (Ω)
-4045,303
-3026,108
-2015,458
-109,395
05,895
103,791
202,499
252,056
301,706
401,174
50833.8
60595.4
70435.6
80322.5
90243.1
100186.6
110144.2
120112.7
13089.28

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.39–4.5 V → 40–400 kPa absolute (maker: Ua = 1.143 V/bar × p − 0.0714 V (at Us = 5 V))1Calculated from the maker's data
  • NTC: 45,303 Ω at -40 °C falling to 89.3 Ω at 130 °C1
  • Steinhart-Hart fit through -40 °C, 40 °C, 130 °C: A = 1.2991e-3, B = 2.5963e-4, C = 1.6755e-7 (largest error against the maker's table 0.23 °C).1Calculated from the maker's data

Worked conversion

  • At 2.44 V the maker's transfer line gives 220 kPa absolute (31.9 psia).1Calculated from the maker's data
  • At 25 °C the element is 2,056 Ω; with a 1 kΩ pull-up to 5 V the ECU sees 5 × 2,056 / (2,056 + 1,000) = 3.364 V.1Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (9 rows)Calculated from the maker's data
Output (V)Pressure (kPa absolute)Pressure (psia)
0.5507.25
193.813.6
1.5137.519.95
2181.326.29
2.522532.63
3268.738.97
3.5312.445.32
4356.251.66
4.5399.958

Interpolated between the maker's published points; nominal values with no tolerance band.

Temperature sensor (NTC): resistance and ECU input voltage (19 rows)Calculated from the maker's data
Temperature (°C)Resistance (Ω)V at 1 kΩ pull-up to 5 VV at 2.2 kΩ pull-up to 5 V
-40453034.8924.768
-30261084.8164.611
-20154584.6964.377
-1093954.5194.051
058954.2753.641
1037913.9563.164
2024993.5712.659
2520563.3642.415
3017063.1522.184
4011742.71.74
50833.82.2731.374
60595.41.8661.065
70435.61.5170.826
80322.51.2190.639
90243.10.9780.498
100186.60.7860.391
110144.20.630.308
120112.70.5060.244
13089.280.410.195

Resistance from the maker's table. The maker does not state a pull-up; 1 kΩ and 2.2 kΩ are example values: use your ECU's actual pull-up.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium2
Haltech (Elite / Nexus)Configurable (generic input)Analog voltage input (AVI). Haltech's wiring diagram says inputs are user definable in software; enter the maker's transfer function.67
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium8
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). MoTeC's sensor pages show a manual-calibration option in M1 Tune.Medium910
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs. ECUMaster lists user-defined sensor characteristics for some functions.Medium11
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium12
MaxxECUConfigurable (generic input)Extra 0-5 V input (6 on the RACE). The public page does not describe calibration entry.Medium13
Holley (Terminator X / EFI)Configurable (generic input)'5' analog input, set up as a custom sensor in Holley's software (per the wiring manual).14

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Bosch recommends an RC low-pass filter of about 2 ms at the ECU input, engine oil (5W40) rather than silicone grease on the O-ring, and avoiding mis-pinning (it survives 5 minutes at 0.3 A).1

Failure modes and checks

Pressure noisy at idle

Likely cause No input filtering

Check Add or enable an RC filter of about 2 ms as Bosch recommends.Medium1

Reading drifts after wet weather

Likely cause Condensate in the port

Check Mount within ±60° of vertical, port downward.Medium1

Test it with a multimeter

  • Key on, engine off, port open to air: back-probe signal to sensor ground and expect about 1.09 V; the supply pin should read the ECU's 5 V reference.1Calculated from the maker's data
  • Unplugged, measure resistance across the two element pins: about 2,056 Ω at 25 °C, falling as it warms (compare with the table).1Calculated from the maker's data

Frequently asked

What is the calibration of the Bosch 4-bar MAP sensor?

For the PST 4 (0 261 230 423): output = 1.143 V/bar × absolute pressure − 0.0714 V at 5 V supply. That gives 0.386 V at 0.4 bar and 4.5 V at 4 bar.1

How much boost can a 4-bar MAP sensor read?

Up to 4 bar absolute, about 3 bar (44 psi) of boost at sea level. The PST 4 tolerates 6 bar absolute without damage.Medium1

Related

Use it with GAINS

Bosch PST 4 4-bar TMAP sensor on GAINS hardware

ECU2Internal 4-bar MAP

Pins
On the ECU2 pin map
Pull-up
Not used
Shielding
Not needed

The ECU2 has its own 4-bar MAP on a hose barb, so an external MAP is optional (finer resolution or a second pressure such as boost before the throttle).Medium2

ECU2AVI pressure (pull-up off) + AVI temperature (pull-up on)

Pins
On the ECU2 pin map
Pull-up
To be confirmed
Shielding
Not needed

Pressure on one AVI with the pull-up off; the NTC on a second AVI with the pull-up on.Medium2

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.23

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

14 sources
  1. Pressure Sensor Combined PST 4 data sheet 70524939 · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-10-27
  2. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  3. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  4. PST 4 product page · Bosch Motorsport · vendor-doc · retrieved 2026-10-27
  5. Nexus R3 wiring diagram (HT-193000_WD) · Haltech · vendor-doc · retrieved 2026-10-27
  6. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-10-27
  7. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  8. TMAP Sensor product page · MoTeC · vendor-doc · retrieved 2026-10-27
  9. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-10-27
  10. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  11. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-10-27
  12. HP / Dominator EFI wiring manual 199R10555 · Holley · vendor-doc · retrieved 2026-10-27

Not yet indexed: fewer than 3 FAQs.