Bosch · Analog 0-5 V (ratiometric)

Bosch PS-AA 1.15 bar absolute air pressure sensor (0 261 230 216)

Bosch 0 261 230 216

Bosch 0 261 230 216 is the PS-AA absolute air pressure sensor in its 0.1-1.15 bar (1.5-16.7 psi) range, built for air box pressure and well suited to barometric or naturally aspirated MAP duty. It runs on 5 V with a ratiometric 0.4-4.65 V output at 4,048 mV per bar. Pins: 1 supply, 2 ground, 3 signal.2

Key specifications

Measures: Absolute air pressure, 0.1-1.15 bar (1.5-16.7 psi). Output: Analog 0-5 V (ratiometric).

Range
  • 0.1-1.15 bar absolute1.5-16.7 psi
  • 5 bar maximum72.5 psi
Sourced2
Output0.4-4.65 V ratiometric at 5 V supplySourced2
Sensitivity / offset
  • 4,048 mV/bar
  • -4.8 mV
Sourced2
Tolerance± 0.016 bar (± 1.52 % FS) at 5 V, compensated 10-85 °CSourced2
Supply4.75-5.25V, 9 mA16 V maxSourced2
Response time1msT10/90Sourced2
Operating temperature-40 to 130°C-40 to 266 °FSourced2
Mounting
  • M6 screw
  • 12.05 mm fitting with 7.59 x 2.62 mm O-ring
  • 20 g
Sourced2
Part numberMakerNote
0 261 230 216BoschPrinted 0261.230.216 on the data sheet (PS-AA, 0.1-1.15 bar)2

Pinout and connector

123Schematic, pin-number order (positions not published)
Schematic in pin-number order: the maker does not publish cavity positions. Mating face labels. Pin functions from the maker's document. Our drawing from the published pin list, not a maker drawing.
  • Supply
  • Ground / return
  • Signal
  • Shield
  • Not used / not listed
Download pinout (SVG)
PinFunction (as published)Typical ECU inputWire note
1Supply (US, 5 V)+5 V sensor reference—
2GroundSensor groundReturn to sensor ground, not chassis
3Pressure signalAnalog voltage input (pull-up off)—

Pin functions as Bosch publishes them; the drawing is a schematic in pin order, not the connector's true cavity layout.2 The ECU-input and wire columns are our general guidance, not the maker's.

Connector: Bosch Compact 1.1a, 3-pole, coding 1 (RB-COMP 1.1a/3P/Kod.1); mating part D261.205.366-012 Connector library

Terminals and seals: Not listed: the data sheet gives the mating housing only.

Transfer function and calibration data

Pressure transfer at 5 V2

Ua = 4.048 V/bar × p − 0.0048 V (at Us = 5 V)

0.41.4622.5253.5874.650.10.36250.6250.88751.15Absolute pressure (bar)Output (V)

Points computed from Bosch's sensitivity and offset.

Show the 5 data points
Absolute pressure (bar)Output (V)
0.10.4
0.41.614
0.72.829
14.043
1.154.65

How it's calibrated

ECU-neutral: enter these values in whichever ECU you use. Nominal values without the maker's tolerance band.

Transfer function

  • 0.4–4.65 V → 10–115 kPa absolute (maker: Ua = 4.048 V/bar × p − 0.0048 V (at Us = 5 V))2Calculated from the maker's data

Worked conversion

  • At 2.53 V the maker's transfer line gives 62.6 kPa absolute (9.08 psia).2Calculated from the maker's data
Pressure transfer at 5 V: output voltage to pressure (9 rows)Calculated from the maker's data
Output (V)Pressure (kPa absolute)Pressure (psia)
0.512.51.81
124.83.6
1.537.25.39
249.57.18
2.561.98.97
374.210.77
3.586.612.56
498.914.35
4.5111.316.14

Interpolated between the maker's published points; nominal values with no tolerance band.

Native support across ECUs

ECU platformStatusHow to set it upSource
GAINS ECU2ConceptConfigurable (generic input)Any AVI (AVI1-6; pins 17-20, 14 and 26 on the ECU2): 0-5 V input with the pull-up off. Concept hardware.Medium3
Haltech (Elite / Nexus)Configurable (generic input)One of the 11 0-5 V analog inputs listed for the Nexus R3 (switchable 5 V pull-up, set off); enter the maker's transfer function.Medium5
Link (G4X)Configurable (generic input)Analogue voltage input (9 on the G4X FuryX). Link's public page does not describe how a custom calibration is entered.Medium6
MoTeC (M1)Configurable (generic input)Analogue voltage input (17 on the M150). The public page does not describe calibration entry for this sensor.Medium7
ECUMaster (EMU Black)Configurable (generic input)One of 9 analog 0-5 V inputs (10-bit) on the EMU Black. The page lists user-defined characteristics only for fuel pressure.Medium8
AEM (Infinity)Configurable (generic input)Analog 0-5 V input (12-bit). AEM's spec sheet does not say how a custom calibration is entered.Medium9
MaxxECUConfigurable (generic input)Extra 0-5 V input on the RACE. The public page does not describe calibration entry.Medium10
Holley (Terminator X / EFI)UnverifiedNot checked: we cite only public product pages, and none for Holley covers this sensor.No public source

Third-party rows come only from each vendor's public product pages, sensor lists and spec sheets, retrieved on the dates listed in Sources; we do not use ECU software, help files, base maps or calibration files, and reproduce no vendor calibration values. "Preset listed" means the vendor publicly names this sensor; "Configurable" means a matching generic input is listed. Check the vendor's current documentation before buying.

Trademarks belong to their owners. Names are used only to identify compatible products; no endorsement is implied.

CAD and drawings

We link to the maker's own downloads and do not rehost their CAD or data sheets: the maker's terms do not grant redistribution. Registration may be needed on the maker's site.

Wiring and installation

Wire it as a three-wire ratiometric sensor: 5 V reference to pin 1, sensor ground to pin 2 and pin 3 to an analog input with no pull-up. Bosch recommends a 2 ms RC filter at the ECU input.2

For barometric use, vent the port to still ambient air in a dry spot. For air box pressure, plumb it to the box. Bosch calls for O-ring lubrication with engine oil, not silicone grease.Medium2

Failure modes and checks

Reads about 1 bar with the engine running at idle

Likely cause Sensor port open to atmosphere instead of the manifold, or hose off

Check Compare key-on, engine-off reading with local barometric pressure, then check the reading drops at idle.Medium21

Noisy or jumping pressure trace

Likely cause No input filtering at the ECU

Check Bosch recommends an RC low-pass filter with a time constant of about 2 ms on the ECU input.2

Offset drifts after cold or wet running

Likely cause Condensate in the port

Check Mount the port facing down, within ±60° of vertical as Bosch specifies.2

Test it with a multimeter

  • Key on, engine off, port open to air: back-probe signal to sensor ground and expect about 4.1 V; the supply pin should read the ECU's 5 V reference.2Calculated from the maker's data

Frequently asked

What is the pinout of the Bosch 0 261 230 216?

Pin 1 is the 5 V supply, pin 2 ground and pin 3 the pressure signal, on a 3-pole Bosch Compact connector with mating housing D261.205.366-01.2

Is the PS-AA 1.15 bar a good baro sensor?

Yes, its 0.1-1.15 bar absolute range covers sea-level and high-altitude ambient pressure, and at 4,048 mV per bar it resolves small weather and altitude changes far better than a 3-bar MAP sensor would.Medium2

What is the transfer function of the Bosch PS-AA 1.15 bar?

Bosch gives 4,048 mV per bar with a -4.8 mV offset at 5 V supply, so 0.1 bar reads 0.40 V and 1.15 bar reads 4.65 V. The output is ratiometric, so it scales with the supply.2

Can the PS-AA 1.15 bar read boost?

No. It tops out at 1.15 bar absolute, just above sea-level atmosphere. Bosch sells the same housing in a 0.2-2.5 bar version (0 261 230 284) for pressures above atmosphere.2

Related

Use it with GAINS

Bosch PS-AA 1.15 bar absolute air pressure sensor (0 261 230 216) on GAINS hardware

ECU2AVI (0-5 V, pull-up off)

Pins
On the ECU2 pin map
Pull-up
Off
Shielding
Not needed

A dedicated baro input: any free AVI with the pull-up off. The concept ECU otherwise samples its internal MAP at key-on.Medium3

GAINS hardware is pre-release concept design; pin numbers can change before release and none of it has been tested on a vehicle yet.34

Concept Pre-release hardware. Pin assignments come from the current design documents and may change.

Sources

10 sources
  1. Automotive Handbook, 10th edition (2018) · Robert Bosch GmbH / Wiley · book · retrieved 2026-11-04
  2. Pressure Sensor Air PS-AA data sheet 52308363 (27 Jan 2026) · Bosch Motorsport (Bosch Engineering GmbH) · vendor-doc · retrieved 2026-11-04
  3. internal GAINS internal: ECU2 concept and pin map v0.3 (hardware/mini-ecu/CONCEPT.md §3)
  4. internal GAINS internal: PDM2 input and output specification (hardware/mini-pdm/SPEC.md)
  5. Nexus R3 VCU (HT-193000) product page · Haltech · vendor-doc · retrieved 2026-11-04
  6. M150 product page (M1 series) · MoTeC · vendor-doc · retrieved 2026-10-27
  7. EMU Black product page · ECUMaster · vendor-doc · retrieved 2026-11-04
  8. Infinity Series 5 hardware specification · AEM Electronics · vendor-doc · retrieved 2026-10-27
  9. MaxxECU RACE product page · MaxxECU · vendor-doc · retrieved 2026-11-04