Wiring guide
Raychem DR-25 tubing and heat shrink boots: specs, sizing and adhesives
Raychem DR-25 is TE's diesel-resistant, cross-linked elastomer heat shrink tubing, rated -75 to 150 °C (-103 to 302 °F) with a 2:1 shrink ratio. It resists aviation and diesel fuel, hydraulic fluid and lubricating oil, which is why motorsport harnesses use it as the outer jacket. Matching -25 material heat shrink boots, such as the 202K and 202D straight lipped shapes, seal the harness to the connector backshell, usually with S1125 epoxy.76419
Key takeaways
- DR-25: cross-linked elastomer, -75 to 150 °C, 2:1, full recovery at 175 °C (347 °F).
- Pick tubing so the expanded ID clears the bundle and the recovered ID is smaller than it.
- 202K and 202D boots in -25 material share DR-25's rating; the /225 suffix means adhesive precoated.
- S1125 epoxy cures in 24 h at 20 °C or 1 h at 85 °C and is rated to 150 °C.
- ATUM is adhesive-lined polyolefin-type tubing rated to 110 °C, for sealing rather than fluid-soaked bays.
What Raychem DR-25 is
Raychem DR25 is a flexible, cross-linked elastomer tubing from TE that shrinks 2:1.
TE rates it -75 to 150 °C and lists resistance to aviation and diesel fuel, brake and hydraulic fluid, lubricating oil and water.76
It is single wall and flame retardant, with no adhesive lining. TE lists it against VG 95343 part 5 type D and M23053/16.6
DR-25 sizes
| Size (in) | Expanded ID min (mm) | Recovered ID max (mm) |
|---|---|---|
| 1/8 | 3.2 | 1.6 |
| 3/16 | 4.8 | 2.4 |
| 1/4 | 6.4 | 3.2 |
| 3/8 | 9.5 | 4.8 |
| 1/2 | 12.7 | 6.4 |
| 3/4 | 19.0 | 9.5 |
| 1 | 25.4 | 12.7 |
| 1 1/2 | 38.0 | 19.1 |
| 2 | 51.0 | 25.4 |
TE also lists 3 in and 4 in sizes. DR-25-TW is a thin-wall version.
Choose the size whose expanded ID clears the biggest thing you slide it over (often the connector) and whose recovered ID is below the bundle diameter. With 2:1 tubing, that window is narrow, so a bundle that varies a lot along its length may need two sizes.Medium7
202K and 202D heat shrink boots
Heat shrink boots are moulded shapes that seal a harness to a connector backshell.
| Example part | Material | Rating | Adhesive |
|---|---|---|---|
| 202K153-25/225-0 | Fluid-resistant modified elastomer (-25) | -75 to 150 °C | Precoat, code 225 |
| 202D232-25/225-0 | Fluid-resistant modified elastomer (-25) | -75 to 150 °C | Precoat, code 225 |
| 202K153-100/86-0 | Low fire hazard material (-100) | -30 to 105 °C | Precoat, code 86 |
| 202K153-12-0 | Modified fluoroelastomer (-12) | See note | Purchased separately |
TE's 202K153-12-0 page prints -67 to 392 labelled °C; those numbers equal -55 to 200 °C in °F, so the unit appears to be mislabelled. The meaning of the K and D letters is not stated on the TE pages we read.
Shape code 202 is TE's straight, lipped boot: the lip locks into the backshell groove and the small end shrinks onto the cable.41
The number after the first dash is the material and the code after the slash is the adhesive. In -25 material both 202K153 and 202D232 are fluid-resistant modified elastomer rated -75 to 150 °C, and /225 means adhesive precoated.41
Sizing a boot to the backshell and cable
Size the boot at both ends.
The big end must slide over the backshell and recover onto it, and the small end must recover onto the cable. TE lists 202K153 for cables of 8.4 to 19 mm and 202D232 for 8.4 to 18.3 mm (0.331-0.72 in).41
Adhesives: S1125 epoxy and hot-melt precoats
Unlined boots and tubing need an adhesive to seal and grip.
S1125 is TE's two-part chemical and heat resistant epoxy for -25 parts: 90 minutes pot life, cure 24 h at 20 °C or 1 h at 85 °C, rated to 150 °C.98
Precoated parts carry a hot melt inside instead. TE lists S1030 (-80 to 80 °C) and S1048 (-55 to 120 °C, needs high heat to bond) as tapes and precoats. On metal backshells, preheat until the part is hot to the touch before recovering the boot.8
Adhesive-lined vs non-lined tubing: ATUM vs DR-25
ATUM is TE's adhesive-lined, radiation cross-linked tubing in 3:1 and 4:1 ratios.
| Property | ATUM | DR-25 |
|---|---|---|
| Construction | Adhesive-lined | Single wall, no lining |
| Shrink ratio | 3:1 and 4:1 | 2:1 |
| Operating range | -55 to 110 °C | -75 to 150 °C |
| Full recovery | 110 °C | 175 °C |
| Fluid resistance | Not the stated purpose | Fuels, hydraulic fluids, oils |
TE's ATUM overview gives 110 °C minimum full recovery; some ATUM datasheet listings give 125 °C.
The lining melts and flows to seal against PVC, polyethylene, rubber and metals, which suits connector-to-cable transitions and jacket repairs.5
ATUM is rated -55 to 110 °C (-67 to 230 °F), well below DR-25's 150 °C, and TE does not list it for fuel or oil soak. DR-25 has no lining, so pair it with S1125 or a precoated boot where you need a seal.579
Frequently asked
What is Raychem DR25 made of?
Raychem DR25 is a cross-linked elastomer that TE describes as diesel resistant. It shrinks 2:1, stays flexible from -75 to 150 °C and resists aviation and diesel fuel, hydraulic fluid, brake fluid and lubricating oil. It is single wall with no adhesive lining, so seal the ends with S1125 epoxy or a precoated boot.679
What temperature is DR-25 rated for?
TE rates DR-25 for continuous use from -75 to 150 °C (-103 to 302 °F). Full recovery needs at least 175 °C (347 °F), so use a hot-air gun with enough output and move it evenly. Fluoroelastomer tubing such as RW-200 (to 200 °C) is TE's option for hotter areas.67
What adhesive is used with Raychem heat shrink boots?
For -25 material boots, TE's S1125 two-part epoxy is the usual choice. It has a 90 minute pot life and cures in 24 hours at 20 °C or 1 hour at 85 °C, and is rated to 150 °C. Boots with a slash code, such as /225 or /86, come with a hot-melt precoat instead.984
What is the difference between DR-25 and ATUM?
DR-25 is a 2:1, unlined, fluid-resistant elastomer rated to 150 °C. ATUM is adhesive-lined tubing in 3:1 or 4:1, rated -55 to 110 °C, whose lining melts to make a moisture seal. Use DR-25 as an engine-bay harness jacket, and ATUM to seal splices, breakouts and repairs away from fuel and oil.65
How do you size a heat shrink boot?
Measure the connector backshell and the cable. The boot's big end must clear the backshell before shrinking and grip it after, and the small end must recover below the cable diameter. TE lists 202K153 boots for 8.4 to 19 mm cables; the product drawing gives the expanded and recovered diameters.Medium4
Keep going
Related
Sources
9 sources
- 202D232-25/225-0 heat shrink boot product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- 202K153-100/86-0 heat shrink boot product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- 202K153-12-0 heat shrink boot product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- 202K153-25/225-0 heat shrink boot product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- ATUM heat shrink tubing overview · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- DR-25-1-0-SP heat shrink tubing product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- High-performance heat shrinkable harnessing tubing (DR-25, RW-200, RT555 and others) · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- Hot-melt adhesive tapes and molded-part adhesives (S1030, S1048, S1125, precoats) · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
- S1125-KIT-5 epoxy adhesive product page · TE Connectivity (Raychem) · vendor-doc · retrieved 2026-10-27
Facts come from manufacturer documents and distributor spec pages, read on the retrieval date shown. Part numbers and ratings change: confirm against the maker's current drawing before you order. Manufacturer names identify parts only; no affiliation is implied.