Wiring guide
Automotive wire types: TXL vs GXL vs SXL, GPT, FLRY, AVSS and Tefzel
TXL wire is SAE J1128 automotive primary wire with thin-wall cross-linked polyethylene (XLPE) insulation, rated to 125 °C (257 °F) on maker datasheets. GXL uses the same insulation with a thicker wall and SXL the thickest. GPT and Japanese AVSS are PVC rated 80 °C, European FLRY-B is PVC rated 105 °C, and M22759 Tefzel (ETFE) is the 150 °C, 600 V option used in many race car wiring harnesses.1210119764
Key takeaways
- TXL, GXL and SXL share 125 °C XLPE insulation. Only the wall changes: 0.016, 0.023 and 0.030 in (0.41, 0.58, 0.76 mm) at 18 AWG on Sycor's sheets.
- GPT and AVSS are PVC rated 80 °C (176 °F). Keep them in the cabin, away from engine heat.
- FLRY-B is thin-wall PVC rated -40 to 105 °C for 3,000 h. JASO AVSSX (100 °C) and AESSX (120 °C) are the cross-linked Japanese versions.
- M22759/32 Tefzel (ETFE) is rated 150 °C and 600 V, and is thinner than TXL at every gauge listed.
- Check the finished insulation OD against the connector seal range, not just the gauge.
TXL vs GXL vs SXL: same insulation, different wall
SAE J1128 names three cross-linked polyethylene types by wall thickness: TXL (extra thin), GXL (thin) and SXL (standard).
- -51 to 125 °C (-60 to 257 °F) for TXL and SXL
- Sycor lists GXL at -40 or -51 to 125 °C depending on gauge
- 0.013 in for 22-14 AWG0.33 mm
- 0.015 in at 12 AWG
- 0.017 in at 10 AWG
| AWG | TXL wall / OD | GXL wall / OD | SXL wall / OD |
|---|---|---|---|
| 20 | 0.016 / 0.070 in (0.41 / 1.78 mm) | 0.023 / 0.085 in (0.58 / 2.16 mm) | 0.029 / 0.096 in (0.74 / 2.44 mm) |
| 18 | 0.016 / 0.079 in (0.41 / 2.01 mm) | 0.023 / 0.092 in (0.58 / 2.34 mm) | 0.030 / 0.107 in (0.76 / 2.72 mm) |
| 16 | 0.016 / 0.089 in (0.41 / 2.26 mm) | 0.023 / 0.103 in (0.58 / 2.62 mm) | 0.032 / 0.120 in (0.81 / 3.05 mm) |
| 14 | 0.016 / 0.103 in (0.41 / 2.62 mm) | 0.023 / 0.117 in (0.58 / 2.97 mm) | 0.035 / 0.141 in (0.89 / 3.58 mm) |
| 12 | 0.018 / 0.126 in (0.46 / 3.20 mm) | 0.026 / 0.142 in (0.66 / 3.61 mm) | 0.037 / 0.163 in (0.94 / 4.14 mm) |
| 10 | 0.020 / 0.155 in (0.51 / 3.94 mm) | 0.031 / 0.179 in (0.79 / 4.55 mm) | 0.041 / 0.193 in (1.04 / 4.90 mm) |
Sycor nominal values; other makers differ slightly (Prestolite lists 18 AWG TXL at 0.078-0.082 in OD depending on stranding).
Sycor lists all three as XLPE rated to 125 °C (257 °F), so the choice is about size, weight and abrasion margin, not heat.121011
The wall difference shows up in bundle size. A 16 AWG TXL wire is 0.089 in (2.26 mm) over the insulation, while the same gauge in SXL is 0.120 in (3.05 mm), about 35% larger in diameter.1211
GPT and other PVC primary wire
GPT (general purpose thermoplastic) is the PVC member of SAE J1128.
Printed as 0.19 in, which is out of sequence with the 16 AWG (0.105 in) and 12 AWG (0.144 in) values
The Sycor page prints 0.19 in for 14 AWG GPT; the neighbouring sizes suggest a typo. Confirm with the maker before using it to size a seal.Conflict9Sycor rates it -40 to 80 °C (-40 to 176 °F), which is fine behind the dash but leaves little margin near an engine.9
GPT walls match GXL at 20-14 AWG (0.023 in, 0.58 mm), so the outside diameters are close. The difference is the material: PVC softens with heat, while cross-linked polyethylene does not melt.Medium910
ISO 6722 temperature classes
ISO 6722 covers 60 V and 600 V single-core road-vehicle cables and grades insulation by temperature class.
| Class | Upper limit |
|---|---|
| A | 85 °C (185 °F) |
| B | 100 °C (212 °F) |
| C | 125 °C (257 °F) |
| D | 150 °C (302 °F) |
| E | 175 °C (347 °F) |
| F | 200 °C (392 °F) |
| G | 225 °C (437 °F) |
| H | 250 °C (482 °F) |
From the abstract of ISO 6722:2002, which is withdrawn. We could not read the current ISO 6722-1 text to confirm how its class labels (such as T2 on Prysmian's FLRY-B sheet) map to these letters.
The 2002 edition abstract lists eight classes from A (85 °C) to H (250 °C), each starting at -40 °C.8
Current datasheets cite ISO 6722-1 and may use a different class label. Prysmian's FLRY-B sheet, for example, quotes "class T2" and a 105 °C, 3,000 h rating. Read the class and the rated hours together.6
FLRY-B: European thin-wall PVC
FLRY is the common European thin-wall PVC cable.
The suffix is commonly read as the conductor stranding class (B = finer, more flexible strands)
We did not find a manufacturer or standard text that defines the A and B suffixes. Check the stranding column on the datasheet.Researched, unverified| Size (mm²) | Strands | Min wall (mm) | Outside diameter (mm) | Max resistance, bare (mΩ/m at 20 °C) |
|---|---|---|---|---|
| 0.35 | 12 | 0.20 | 1.2-1.4 | 54.4 |
| 0.5 | 16 | 0.22 | 1.4-1.6 | 37.1 |
| 0.75 | 24 | 0.24 | 1.7-1.9 | 24.7 |
| 1.0 | 32 | 0.24 | 1.9-2.1 | 18.5 |
| 1.5 | 30 | 0.24 | 2.2-2.4 | 12.7 |
| 2.5 | 50 | 0.28 | 2.7-3.0 | 7.60 |
| 4 | 56 | 0.32 | 3.4-3.7 | 4.71 |
| 6 | 84 | 0.32 | 4.0-4.3 | 3.14 |
Prysmian's FLRY-B datasheet lists PVC insulation to ISO 6722-1, rated -40 to 105 °C (-40 to 221 °F) for 3,000 h, with bare or tinned copper conductors.6
The same sheet lists approvals against Ford, GM, FCA, JLR, Volvo and Renault-Nissan specifications. That list is a quick way to tell a datasheet-backed cable from an unbranded reel.6
JASO AVSS, AVSSX and AESSX
Japanese harness wire follows JASO D 611.
| Type | Insulation | Rating | Sizes listed |
|---|---|---|---|
| AVSS | PVC | -40 to 80 °C (3,000 h) | 0.3-2f mm² |
| AVSSX | E-beam cross-linked PVC | up to 100 °C (10,000 h) | 0.50-2.00 mm² |
| AESSX | E-beam cross-linked polyethylene, low halogen | up to 120 °C (10,000 h) | 0.30-2.00 mm² |
Ratings are per the named makers; other makers may rate the same JASO type differently.
AVSS is thin-wall PVC rated -40 to 80 °C for 3,000 h, the same heat class as GPT.7
The cross-linked versions carry an X. Acome rates its AVSSX (e-beam cross-linked PVC) to 100 °C and its AESSX (cross-linked polyethylene) to 120 °C, both for up to 10,000 h.21
M22759 Tefzel (ETFE) wire
Tefzel wire is the trade name people use for ETFE-insulated M22759 (AS22759) aerospace wire.
| AWG | M22759/16 max OD | M22759/32 max OD | TXL nominal OD (Sycor) |
|---|---|---|---|
| 22 | 0.054 in (1.37 mm) | 0.045 in (1.14 mm) | not listed (22 AWG TXL: 0.062 in, 1.57 mm) |
| 20 | 0.062 in (1.57 mm) | 0.052 in (1.32 mm) | 0.070 in (1.78 mm) |
| 18 | 0.073 in (1.85 mm) | 0.062 in (1.57 mm) | 0.079 in (2.01 mm) |
| 16 | 0.081 in (2.06 mm) | 0.070 in (1.78 mm) | 0.089 in (2.26 mm) |
| 14 | 0.095 in (2.41 mm) | 0.088 in (2.24 mm) | 0.103 in (2.62 mm) |
| 12 | 0.117 in (2.97 mm) | 0.107 in (2.72 mm) | 0.126 in (3.20 mm) |
M22759 values are nominal plus tolerance from the NASA NEPP parts list pages.
Both slash sheets below are tin-coated copper, rated 600 V and 150 °C (302 °F).34
M22759/16 is the medium-weight wall and /32 the light-weight wall. At 20 AWG, /32 is 0.052 in (1.32 mm) maximum against 0.070 in (1.78 mm) nominal for TXL, which is why motorsport harness builders use it to save diameter and weight.412
Chinese-made and unbranded wire
Much harness wire is made in China and sold under SAE, ISO or JASO type names.
Chinese automotive industry standard for thin-wall low-voltage cables
A standards-catalogue listing describes QC/T 730-2005 this way and marks it obsolete; we could not read the standard or confirm whether it is equivalent to ISO 6722.Researched, unverifiedA type name alone tells you little: ask for the datasheet that names the standard, the temperature class with its rated hours, and the wall per size, the way Prysmian's FLRY-B sheet does.Medium6
Which wire where
Pick insulation by the hottest place the wire passes, then check that the finished OD fits the connector seal.
| Type | Insulation | Upper rating | Typical place |
|---|---|---|---|
| GPT | PVC | 80 °C | Cabin, trunk |
| AVSS | PVC | 80 °C | Cabin |
| FLRY-B | PVC | 105 °C (3,000 h) | Cabin, body |
| AESSX | Cross-linked PE | 120 °C | Engine bay |
| TXL / GXL / SXL | Cross-linked PE | 125 °C | Engine bay, chassis |
| M22759/16, /32 | ETFE | 150 °C | Engine bay, race harnesses |
The 'typical place' column is general practice, not a rating. Near exhaust parts, add heat sleeving and route away from the heat source.
TE's stamped size 20 Deutsch contact, for example, accepts 1.9-3.2 mm insulation, so 20 AWG TXL at 1.78 mm sits below its range.1312
Frequently asked
What is the difference between TXL and GXL wire?
The difference is wall thickness. Both are SAE J1128 cross-linked polyethylene wire rated to 125 °C, but TXL has a thinner wall: 0.016 in (0.41 mm) against 0.023 in (0.58 mm) for GXL at 18 AWG on Sycor's datasheets. TXL saves diameter and weight in a dense harness; GXL gives a little more abrasion margin.1210
What temperature is TXL wire rated for?
TXL wire is rated to 125 °C (257 °F). Sycor lists its TXL at -51 to 125 °C and Prestolite rates its TXL insulation at 125 °C. The cross-linked polyethylene does not melt like PVC, which is why TXL is the usual engine-bay choice in SAE-sized harnesses. Above that, step up to 150 °C ETFE (M22759) or add sleeving.1254
What is Tefzel wire?
Tefzel wire is ETFE-insulated aerospace wire built to M22759 (AS22759) slash sheets. M22759/16 (medium weight) and /32 (light weight) are both tin-coated copper rated 600 V and 150 °C. The /32 wall is thin: 20 AWG measures 0.052 in (1.32 mm) maximum, which suits compact race car wiring harnesses.34
Is FLRY wire the same as TXL?
No. FLRY is a European thin-wall cable with PVC insulation built to ISO 6722; Prysmian rates its FLRY-B at -40 to 105 °C for 3,000 h. TXL is SAE J1128 wire with cross-linked polyethylene insulation rated to 125 °C. Sizes are similar but metric: 0.5 mm² FLRY-B is 1.4-1.6 mm over the insulation.612
Can I use AVSS wire in an engine bay?
Standard AVSS is PVC rated -40 to 80 °C, so it is a poor choice near an engine. The cross-linked Japanese versions are better: Acome rates AVSSX to 100 °C and AESSX (cross-linked polyethylene) to 120 °C. For the hottest areas, TXL or GXL at 125 °C or ETFE wire at 150 °C give more margin.72112
Does insulation thickness matter for sealed connectors?
Yes. Sealed connectors seal on the insulation, so the outside diameter must sit inside the contact or grommet range. TE's size 20 stamped Deutsch contact takes 1.9-3.2 mm insulation, while 20 AWG TXL is 1.78 mm. Check the range on the contact page before choosing thin-wall wire.1312
Keep going
Related
Sources
13 sources
- T120 wires JASO AESSX product page · Acome · vendor-doc · retrieved 2026-10-27
- T100 wires JASO AVSSX product page · Acome · vendor-doc · retrieved 2026-10-27
- AS22759/16 wire, ETFE insulated, medium weight, 600 V, 150 °C (parts list page) · NASA NEPP Parts Selection List · standard · retrieved 2026-10-27
- AS22759/32 wire, ETFE insulated, light weight, 600 V, 150 °C (parts list page) · NASA NEPP Parts Selection List · standard · retrieved 2026-10-27
- SAE J1128 TXL automotive primary wire 125 °C datasheet rev 1 (2011-02-02) · Prestolite Wire (hosted by Zoro / IEWC) · vendor-doc · retrieved 2026-10-27
- FLRY-B automotive cable datasheet DF 049-2000 index V (issued 2020-10-06) · Prysmian Kabel und Systeme GmbH · vendor-doc · retrieved 2026-10-27
- AVSS automotive cable (JASO D 611) product page · RR Kabel · vendor-doc · retrieved 2026-10-27
- ISO 6722:2002 Road vehicles, 60 V and 600 V single-core cables: abstract and status · Standards Council of Canada (standards database) · standard · retrieved 2026-10-27
- Type GPT wire, general purpose thermoplastic (SAE J1128) product page · Sycor Technology · vendor-doc · retrieved 2026-10-27
- Type GXL wire, primary thin wall (SAE J1128) product page · Sycor Technology · vendor-doc · retrieved 2026-10-27
- Type SXL wire, primary standard wall (SAE J1128) product page · Sycor Technology · vendor-doc · retrieved 2026-10-27
- Type TXL wire, primary extra thin wall (SAE J1128) product page · Sycor Technology · vendor-doc · retrieved 2026-10-27
- 1060-20-0122 pin, stamped and formed, size 20: product page · TE Connectivity · vendor-doc · retrieved 2026-10-27
Facts come from manufacturer documents and distributor spec pages, read on the retrieval date shown. Part numbers and ratings change: confirm against the maker's current drawing before you order. Manufacturer names identify parts only; no affiliation is implied.