BorgWarner EFR 6758 compressor map

EFR54 mm inducer67 mm exducerModelled estimate

Map data from BorgWarner Inc., retrieved 2026-10-25.

The BorgWarner EFR 6758 compressor peaks at 74% efficiency around 32 lb/min and a pressure ratio of 2.2. Its map reaches a pressure ratio of about 4.1, and at a pressure ratio of 2 it flows from about 12 lb/min (surge) to 54 lb/min (choke side).

Peak efficiency
74%
island 24–39 lb/min, PR 1.8–2.6
Surge line
5–45
lb/min, from PR 1.2 to 4.1
Choke side, max flow
54
lb/min (0.405 kg/s)
Pressure-ratio reach
4.06
about 45 psi boost at sea level, before losses
Map width at PR 2
4.6×
choke flow ÷ surge flow
Outlet temp at peak island
256 °F
from 77 °F inlet, PR 2.2, 74% efficiency

Flow range

0306090120

Light band: usable flow at a pressure ratio of 2 (surge to choke side). Solid band: the 74% island. Scale 0–120 lb/min. We show figures derived from the map, not the map itself. See the maker's compressor map for the full islands and speed lines.

Surge and choke

Surge is the left-hand limit: too little flow for the pressure ratio, so air reverses through the wheel. On this map the surge line runs from about 5.5 lb/min (0.041 kg/s) at a pressure ratio of 1.2 to 45.0 lb/min (0.340 kg/s) at 4.1. Keep the full-load operating line to the right of it, with margin for transients.

Choke is the right-hand limit, where efficiency falls away and the wheel can't pass more air. The digitised choke side spans 44.9 lb/min (0.340 kg/s) to 53.6 lb/min (0.405 kg/s) across pressure ratios 1.2–4.1. It is the lowest efficiency contour the maker draws (58%), not a measured choke line.

Shaft-speed lines on the map run from 48k to 154k rpm.

Engines it suits

We ran every engine preset in the turbo matcher at three boost levels and ranked all 20 maps for each. These are the engines where this compressor came out in the top three and the whole operating line stayed on the map, with no surge or choke. Modelled estimate

15 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
N54 3.0 TT · BMW3 of 203,500 rpm51%2.20
N55 3.0 T · BMW3 of 203,500 rpm51%2.20
6G72TT (3000GT VR-4) · Mitsubishi3 of 203,500 rpm52%2.20
M52TU / M54 · BMW3 of 203,500 rpm41%2.20
FA20 / FA24 D-4S (86 / BRZ / GR86) · Toyota/Subaru3 of 204,500 rpm11%2.20
K24A2 (TSX) · Honda3 of 204,500 rpm7%2.20
EJ257 (STI) · Subaru3 of 204,500 rpm4%2.20
EJ255 (WRX / Legacy GT / Forester XT) · Subaru3 of 204,500 rpm10%2.20

22 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
FA20 / FA24 D-4S (86 / BRZ / GR86) · Toyota/Subaru3 of 204,500 rpm5%2.69
EJ255 (WRX / Legacy GT / Forester XT) · Subaru3 of 204,500 rpm6%2.69
K24A1 / K24A4 (CR-V / Accord) · Honda3 of 204,500 rpm1%2.69
KA24DE · Nissan3 of 204,500 rpm2%2.69
2.3 EcoBoost · Ford3 of 205,000 rpm1%2.69
MZR 2.3 DISI (Mazdaspeed) · Mazda3 of 205,000 rpm1%2.69

30 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
2JZ-GTE VVT-i · Toyota3 of 204,000 rpm7%3.25
2JZ-GTE (non-VVT-i) · Toyota3 of 204,000 rpm7%3.25
B58 3.0 T · BMW3 of 204,000 rpm7%3.25

Assumptions (the matcher's defaults): stock torque-curve VE shape scaled to 92% peak, full boost from 3,500 rpm to redline, 120 °F charge after the intercooler, 77 °F ambient at sea level, 1.5 psi charge-side and 0.5 psi inlet losses, gasoline. A compressor map says nothing about spool or transient response; the turbine housing decides much of that. The interactive turbo matcher opens once map review is complete.

Turbine housings

The maker's turbine flow chart for this frame lists 3 housings. Highest corrected gas flow digitised for each:

HousingMax corrected flow (corrected flow parameter)At expansion ratio
0.64 A/R (58mm 0.64a/r curve)0.03.00
0.80 A/R twin-scroll T4 (chart: 58mm 0.80 & 0.85a/r share one curve)0.03.00
0.85 A/R T25/V-band (chart: 58mm 0.80 & 0.85a/r share one curve)0.03.00

Expansion ratio and flow as labelled on the maker's chart. See A/R ratio for how housing size trades spool against top-end flow.

Maker's published spec

Family
EFR
Bearing
dual ceramic ball bearing, metal cage
Compressor wheel
54 mm inducer, 67 mm exducer
Turbine housing A/R
0.64 (-A T25), 0.85 (-F T25), 0.85 (-F(v) V-band), 0.80 (-G T4 twin), 0.85 (-I V-band, no IWG)

Compare

Related

How these numbers are made

Method
manual reading from the maker's published map image at vector resolution (the datasheet PDF embeds the map as vector paths; curves were extracted from the PDF geometry, calibrated against the gridlines, contour fragments identified and joined by hand, open contours closed along the surge line / top speed line, then resampled)
Accuracy
+/-0.3 lb/min and +/-0.01 PR on traced lines (vector source); island polygons are resampled to ~20 points and contours that the map leaves open (cut by label gaps, the surge line or the max-speed line) were closed along the map boundary or by short chords, so island edges near those closures are approximate (+/-1 lb/min).
Flow correction
298.2 K, 100.00 kPa. The EFR datasheet map does not state its correction reference. Value used is BorgWarner's own documented convention: the BorgWarner MatchBot sizing tool (borgwarner.com/matchbot, bot.js) corrects compressor flow as m*sqrt((T+460)/537 R)/(P_kPa/100), i.e. 537 R (77 F, ~298 K) and 100 kPa. Flow axis is 'Compressor Flow (lb/min)'. The PR basis is not stated on the datasheet (BorgWarner's EFR Technical Training Book maps label PR as p2t/p1t, total-to-total).
Pressure-ratio basis
Not stated on the maker's map

Every figure on this page is a modelled estimate derived from that digitisation. It is not a flow-bench or dyno result and makes no power claim.

Sources

BorgWarner and model names are trademarks of their owners and identify the part only. No affiliation or endorsement is implied.