Garrett GTX3582R Gen II compressor map

GTX Gen IIGTX35 frame66 mm inducer82 mm exducerModelled estimate

Map data from Garrett Motion, retrieved 2026-10-25.

The Garrett GTX3582R Gen II compressor peaks at 76% efficiency around 40 lb/min and a pressure ratio of 2.1. Its map reaches a pressure ratio of about 4.1, and at a pressure ratio of 2 it flows from about 17 lb/min (surge) to 68 lb/min (choke side).

Peak efficiency
76%
island 27–53 lb/min, PR 1.5–2.7
Surge line
8–39
lb/min, from PR 1.3 to 4.1
Choke side, max flow
82
lb/min (0.620 kg/s)
Pressure-ratio reach
4.12
about 46 psi boost at sea level, before losses
Map width at PR 2
3.9×
choke flow ÷ surge flow
Outlet temp at peak island
243 °F
from 77 °F inlet, PR 2.1, 76% efficiency

Flow range

0306090120

Light band: usable flow at a pressure ratio of 2 (surge to choke side). Solid band: the 76% island. Scale 0–120 lb/min. We show figures derived from the map, not the map itself. See the maker's compressor map for the full islands and speed lines.

The 75% efficiency island is not resolved on this map.

Surge and choke

Surge is the left-hand limit: too little flow for the pressure ratio, so air reverses through the wheel. On this map the surge line runs from about 8.0 lb/min (0.061 kg/s) at a pressure ratio of 1.3 to 39.4 lb/min (0.298 kg/s) at 4.1. Keep the full-load operating line to the right of it, with margin for transients.

Choke is the right-hand limit, where efficiency falls away and the wheel can't pass more air. The digitised choke side spans 28.0 lb/min (0.212 kg/s) to 82.1 lb/min (0.620 kg/s) across pressure ratios 1.1–4.1. It is the lowest efficiency contour the maker draws (60%), not a measured choke line.

Shaft-speed lines on the map run from 50k to 130k rpm.

Engines it suits

We ran every engine preset in the turbo matcher at three boost levels and ranked all 20 maps for each. These are the engines where this compressor came out in the top three and the whole operating line stayed on the map, with no surge or choke. Modelled estimate

30 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
1UZ-FE / 3UZ-FE V8 · Toyota3 of 20—7%3.25
Lambda 3.8 MPI · Hyundai3 of 20—0%3.25

Assumptions (the matcher's defaults): stock torque-curve VE shape scaled to 92% peak, full boost from 3,500 rpm to redline, 120 °F charge after the intercooler, 77 °F ambient at sea level, 1.5 psi charge-side and 0.5 psi inlet losses, gasoline. A compressor map says nothing about spool or transient response; the turbine housing decides much of that. The interactive turbo matcher opens once map review is complete.

Turbine housings

The maker's turbine flow chart for this frame lists 6 housings. Highest corrected gas flow digitised for each:

HousingMax corrected flow (lb/min)At expansion ratio
84 trim 1.06 A/R31.72.75
84 trim 1.01 A/R29.83.50
84 trim 0.83 A/R27.63.50
84 trim 0.82 A/R26.92.75
84 trim 0.63 A/R24.33.50
84 trim 0.61 A/R22.83.50

Expansion ratio and flow as labelled on the maker's chart. See A/R ratio for how housing size trades spool against top-end flow.

Maker's published spec

Family
GTX Gen II
Bearing
8mm dual ceramic ball bearing
Compressor wheel
66 mm inducer, 82 mm exducer
Turbine housing A/R
0.61, 0.63, 0.82, 0.83, 1.01, 1.06
Maker's engine size range
2.0L-4.5L

Compare

Related

How these numbers are made

Method
manual reading from the maker's published map image at 1714x2048 px (contours traced by eye on a calibrated pixel grid; this map's dense, closely labelled contours were not scan-assisted)
Accuracy
about +/-3% of axis span overall; up to +/-5% near the low-flow island tips where contours converge; 73-76% label-to-contour assignment uncertain (see reference.note)
Flow correction
302.8 K, 96.18 kPa. Not printed on this map image (Garrett's current web maps carry no correction footnote and none was found on garrettmotion.com). Values are Garrett's long-standing convention printed on its legacy GT-series compressor maps: 545 degR (85 degF) and 13.95 psia. Treat as assumed, not maker-stated for this map. Digitizing caveat: on this image the 73-76% labels sit very close together and only six closed inner contours could be separated; they are assigned 76/74/73/72/71/70 from label placement, and no separate 75% contour is included. The 60/65/68% islands are open to the top (max-speed) boundary on Garrett's chart and are closed along that boundary here.
Pressure-ratio basis
Not stated on the maker's map

Every figure on this page is a modelled estimate derived from that digitisation. It is not a flow-bench or dyno result and makes no power claim.

Sources

Garrett and model names are trademarks of their owners and identify the part only. No affiliation or endorsement is implied.