Key facts
Suits
- Club racers and track cars replacing a relay and fuse panel
- Builds already on MoTeC M1 ECUs or C-series dashes
- Cars with up to about 15 switched circuits and a modest total load
What it is and where it fits
The MoTeC PDM15 is the entry model in MoTeC's power distribution range.
It switches power to pumps, fans, lights, solenoids and electronics through solid-state outputs, so the car needs no conventional relays, fuses or circuit breakers for those loads.12
MoTeC lists three current PDMs that share one software tool. The PDM15 has 15 outputs, the PDM30 has 30 in the same case size, and the PDM32 adds Autosport connectors and IP67 sealing for professional builds.2
The PDM15 fits cars with a modest electrical load: a single fuel pump, one or two fans, lights, an ECU and a logger. MoTeC states that several PDMs can share a vehicle when one unit runs out of outputs.2
Hardware and I/O
Eight outputs carry 20 A continuous and seven carry 8 A continuous.
MoTeC quotes typical transient capacity of 115 A and 60 A respectively, which covers the inrush current of motors and lamps at switch-on.1
Total output is about 80 A, so the per-output ratings cannot all be used at once. The 16 switch inputs accept 0 to 51 V, which lets them read dash switches, ignition and simple sensor thresholds.21
The case measures 107.5 × 127.5 × 38.7 mm (4.2 × 5.0 × 1.5 in) and weighs 260 g. Wiring runs through one 34-pin and one 26-pin waterproof connector, with main battery feed on an M6 stud.1
Software and configuration
MoTeC's PDM Manager software sets up the inputs, outputs, CAN messages and switching conditions.
The same tool monitors live channel values, tests outputs and updates firmware.1
Each output's current limit is set in 1 A steps, and outputs switch from a mix of switch inputs, CAN messages and logic. MoTeC quotes up to 200 logic operations, enough for load shedding when battery voltage drops.12
MoTeC gives examples of what that logic allows: restarting a device after a short, switching to a reserve fuel pump if the main pump fails, and shedding loads in order as voltage falls.2
Connectivity and expansion
The PDM15 has one CAN bus.
It reports output currents and fault states over CAN, so a MoTeC dash or logger can display and record them, and teams can send them over telemetry.12
MoTeC lists compatibility with M1-series ECUs and the C125, C127, C1212, C185, C187, C1812, CDL3, L120 and L180 dashes and loggers. Older MoTeC units such as the M800 and ADL3 also appear on the list as discontinued products.1
The PC connects through the MoTeC UTC interface, which MoTeC says is required. The older MoTeC CAN cable does not work with the PDM.1
Installation notes
The PDM sits on the vehicle CAN bus, which needs correct termination.
MoTeC calls for at least one 100 Ω terminating resistor on the bus and a CAN connector wired in for laptop access.1
MoTeC suggests 24 to 20 AWG wire for 8 A outputs and 20 to 16 AWG for 20 A outputs. Long runs may need heavier wire to keep voltage drop acceptable, and too thin a wire can give a poor crimp.1
Generations and variants
The PDM15 (part 14104) and PDM30 (part 14103) share a 108 × 128 × 39 mm case, the same 16 inputs and eight 20 A outputs.
The PDM30 adds 15 more 8 A outputs, raises total current to 100 A and weighs 10 g more.2
The PDM32 (part 14107) is the professional model. It has 32 outputs, 23 inputs, 120 A total output, Autosport connectors and a longer, slimmer 180 × 60 × 28 mm case.2
Specifications
From the maker's published data and independent sources.
Outputs
Inputs, logic and communications
Physical and electrical
| Spec | Value | Source |
|---|---|---|
| Operating voltage | 30 V maximum | 1 |
| Connectors | One 34-pin and one 26-pin waterproof connector, plus one M6 stud for main power | 1 |
| Case size | 107.5 × 127.5 × 38.7 mm (4.23 × 5.02 × 1.52 in) | 1 |
| Weight | 260 g (9.2 oz) | 1 |
| Environmental | Conformal-coated PCB; MoTeC does not list an IP code for this model | 1 |
| Part number | 14104 | 12 |
Strengths and limits
Facts, each cited. Not a score.
Strengths
- Every output has over-current, short-circuit and thermal protection, and current limits are set in 1 A steps.1
- Shares PDM Manager software and CAN diagnostics with the PDM30 and PDM32, so a project can move up the range without new tools.2
- Light at 260 g, with up to 200 logic operations for load shedding and pump failover.12
Limits
- Only seven low-current outputs; MoTeC points cars with many circuits to the PDM30 or PDM32.2
- Total output is 80 A, well below the sum of the per-output ratings.2
- Needs the separate MoTeC UTC interface to connect to a PC.1
- Uses waterproof Tyco-type connectors rather than the Autosport connectors and IP67 case of the PDM32.2
Often compared with
| Product | Category | Key fact |
|---|---|---|
| MoTeC PDM30 | Power distribution modules | Outputs: 30 (8 × 20 A + 22 × 8 A) |
| ECUMaster PMU-16 | Power distribution modules | Outputs: 16 (10 × 25 A + 6 × 15 A) |
| Haltech PD16 PDM | Power distribution modules | Outputs: 16 (10 high-side, 2 half-bridge, 4 × 25 A) |
| AiM PDM32 | Power distribution modules | Outputs: 32 (28 high-side + 4 × 35 A configurable) |
Frequently asked
How many outputs does the MoTeC PDM15 have?
The PDM15 has 15 protected outputs. Eight are rated 20 A continuous with 115 A typical transient capacity, and seven are rated 8 A continuous with 60 A transient capacity. It also has 16 switch inputs and one CAN bus, and MoTeC lists total output current at 80 A.12
What is the difference between the MoTeC PDM15 and PDM30?
The PDM30 has 30 outputs against the PDM15's 15. Both have eight 20 A outputs and 16 inputs, but the PDM30 has 22 rather than seven 8 A outputs. Total current rises from 80 A to 100 A. The case size is the same and the PDM30 weighs 270 g against 260 g.2
What software programs a MoTeC PDM15?
MoTeC PDM Manager configures the PDM15. It sets up inputs, outputs, CAN messages and switching conditions, shows live channel values, tests outputs and updates firmware. The same software covers the PDM30 and PDM32. The laptop connects through the MoTeC UTC interface, not the older MoTeC CAN cable.12
Does the MoTeC PDM15 need a MoTeC ECU?
No source states that a MoTeC ECU is required. The PDM15 switches outputs from its own 16 inputs and logic, and also from CAN messages. MoTeC lists M1-series ECUs and C-series dashes as compatible, so sharing data over CAN is easiest with MoTeC devices. Other CAN devices need matching message setup.Medium1
How much current can a MoTeC PDM15 supply?
MoTeC lists 80 A total output current for the PDM15. Single outputs are rated 20 A or 8 A continuous, with higher short transients for motor and lamp inrush. Because the total is below the sum of the outputs, plan the load so that the loads running at the same time stay within 80 A.21
Related terms
Sources
Numbered as cited above. Hover or tap a citation chip to preview it.
- PDM15 product page and datasheet (part 14104) · MoTeC · vendor-doc · retrieved 2026-11-04
- Power Distribution Modules overview and comparison table · MoTeC · vendor-doc · retrieved 2026-11-04
- MoTeC PDM15 retail listing · GSpeed · reference · retrieved 2026-11-04
- MoTeC PDM15 retail listing · Esslinger Engineering · reference · retrieved 2026-11-04
- What Is A PDM And How Is Haltech's PD16 So Different? · Dragzine · press · retrieved 2026-11-04
A technical overview from published sources; we have not tested this product. Product names are the property of their owners and identify the product only; GAINS is not affiliated with, or endorsed by, the maker.