BorgWarner S372 SX-E compressor map
Map data from BorgWarner Inc., retrieved 2026-10-25.
The BorgWarner S372 SX-E compressor peaks at 74% efficiency around 57 lb/min and a pressure ratio of 2.1. Its map reaches a pressure ratio of about 4.9, and at a pressure ratio of 2 it flows from about 22 lb/min (surge) to 82 lb/min (choke side).
Flow range
Light band: usable flow at a pressure ratio of 2 (surge to choke side). Solid band: the 74% island. Scale 0–120 lb/min. We show figures derived from the map, not the map itself. See the maker's compressor map for the full islands and speed lines.
Surge and choke
Surge is the left-hand limit: too little flow for the pressure ratio, so air reverses through the wheel. On this map the surge line runs from about 9.5 lb/min (0.072 kg/s) at a pressure ratio of 1.4 to 66.3 lb/min (0.501 kg/s) at 4.8. Keep the full-load operating line to the right of it, with margin for transients.
Choke is the right-hand limit, where efficiency falls away and the wheel can't pass more air. The digitised choke side spans 42.5 lb/min (0.321 kg/s) to 110.2 lb/min (0.833 kg/s) across pressure ratios 1.3–4.5. It is the lowest efficiency contour the maker draws (50%), not a measured choke line.
Shaft-speed lines on the map run from 48k to 126k rpm.
Engines it suits
We ran every engine preset in the turbo matcher at three boost levels and ranked all 20 maps for each. These are the engines where this compressor came out in the top three and the whole operating line stayed on the map, with no surge or choke. Modelled estimate
15 psi, single turbo
| Engine | Rank | Efficient from | Lowest surge margin | Peak PR |
|---|---|---|---|---|
| Predator 5.2 SC (GT500) · Ford | 3 of 20 | 4,000 rpm | 30% | 2.20 |
22 psi, single turbo
| Engine | Rank | Efficient from | Lowest surge margin | Peak PR |
|---|---|---|---|---|
| Predator 5.2 SC (GT500) · Ford | 2 of 20 | 4,000 rpm | 13% | 2.69 |
| Coyote Gen 4 · Ford | 3 of 20 | 4,000 rpm | 23% | 2.69 |
30 psi, single turbo
| Engine | Rank | Efficient from | Lowest surge margin | Peak PR |
|---|---|---|---|---|
| Coyote Gen 4 · Ford | 1 of 20 | 4,000 rpm | 12% | 3.25 |
| 4.6 / 5.4 4V (Cobra, GT500, Boss 260/290) · Ford | 1 of 20 | 4,000 rpm | 9% | 3.25 |
| Coyote Gen 3 · Ford | 2 of 20 | 4,000 rpm | 13% | 3.25 |
| 5.7 Hemi (Eagle, VVT 2009+) · Chrysler | 3 of 20 | 3,500 rpm | 33% | 3.25 |
| L76 / L77 (6.0 Gen IV) · GM | 3 of 20 | 3,500 rpm | 37% | 3.25 |
| Coyote Gen 1 · Ford | 3 of 20 | 4,000 rpm | 15% | 3.25 |
| Coyote Gen 2 · Ford | 3 of 20 | 4,000 rpm | 15% | 3.25 |
| LS1 · GM | 3 of 20 | 4,000 rpm | 30% | 3.25 |
Assumptions (the matcher's defaults): stock torque-curve VE shape scaled to 92% peak, full boost from 3,500 rpm to redline, 120 °F charge after the intercooler, 77 °F ambient at sea level, 1.5 psi charge-side and 0.5 psi inlet losses, gasoline. A compressor map says nothing about spool or transient response; the turbine housing decides much of that. The interactive turbo matcher opens once map review is complete.
Compare
Related
How these numbers are made
- Digitised from
- BorgWarner AirWerks S300SX-E 91X79 compressor map (72 mm, Super-Core PN 13009095091), served by BorgWarner MatchBot (BorgWarner Inc., retrieved 2026-10-25)
- Method
- manual reading from the maker's published map image at 928x689 px (left contour branches read from pixel row scans and assigned by counting from the surge line; right/lower branches traced with a pixel line-follower and checked against column scans and zoomed grid-overlaid renders; contours closed along the surge line, the 600 m/s top line, the right-hand boundary, the choke line through the speed-line ends and the 230 m/s bottom line; resampled to 22 points)
- Accuracy
- 0.62-0.74 islands: +/-0.6 lb/min, +/-0.03 PR on traced branches; the lower (fan) branches of 0.62-0.66 between PR 1.3 and 1.8 are closely bunched and partly interpolated (+/-1.5 lb/min). 0.50-0.60 islands are mostly bounded by the map edge (surge, top, right boundary, choke, bottom speed line), so they are close to the whole map outline; their left branches near the surge are +/-0.5 lb/min. Map image is low resolution (~0.13 lb/min and ~0.007 PR per pixel).
- Flow correction
- 298.2 K, 100.00 kPa. The map image states only 'Compressor Flow (lb/min)' and 'Pressure Ratio'; no correction reference or PR basis is printed. Value used is BorgWarner's own documented convention from the BorgWarner MatchBot sizing tool that publishes this map (bot.js corrects compressor flow as m*sqrt((T+460)/537 R)/(P_kPa/100): 537 R ~ 298 K, 100 kPa). Speed lines are labelled in tip speed (m/s); the map ties 561 m/s to 117,533 rpm, and the 230 m/s and 600 m/s lines are converted to rpm with that ratio.
- Pressure-ratio basis
- Not stated on the maker's map
Every figure on this page is a modelled estimate derived from that digitisation. It is not a flow-bench or dyno result and makes no power claim.
Sources
- BorgWarner Inc.: compressor map retrieved 2026-10-25
BorgWarner and model names are trademarks of their owners and identify the part only. No affiliation or endorsement is implied.