BorgWarner S372 SX-E compressor map

AirWerks S300SX-ES300 frameModelled estimate

Map data from BorgWarner Inc., retrieved 2026-10-25.

The BorgWarner S372 SX-E compressor peaks at 74% efficiency around 57 lb/min and a pressure ratio of 2.1. Its map reaches a pressure ratio of about 4.9, and at a pressure ratio of 2 it flows from about 22 lb/min (surge) to 82 lb/min (choke side).

Peak efficiency
74%
island 48–65 lb/min, PR 1.8–2.4
Surge line
10–66
lb/min, from PR 1.4 to 4.8
Choke side, max flow
110
lb/min (0.833 kg/s)
Pressure-ratio reach
4.89
about 57 psi boost at sea level, before losses
Map width at PR 2
3.8×
choke flow ÷ surge flow
Outlet temp at peak island
248 °F
from 77 °F inlet, PR 2.1, 74% efficiency

Flow range

0306090120

Light band: usable flow at a pressure ratio of 2 (surge to choke side). Solid band: the 74% island. Scale 0–120 lb/min. We show figures derived from the map, not the map itself. See the maker's compressor map for the full islands and speed lines.

Surge and choke

Surge is the left-hand limit: too little flow for the pressure ratio, so air reverses through the wheel. On this map the surge line runs from about 9.5 lb/min (0.072 kg/s) at a pressure ratio of 1.4 to 66.3 lb/min (0.501 kg/s) at 4.8. Keep the full-load operating line to the right of it, with margin for transients.

Choke is the right-hand limit, where efficiency falls away and the wheel can't pass more air. The digitised choke side spans 42.5 lb/min (0.321 kg/s) to 110.2 lb/min (0.833 kg/s) across pressure ratios 1.3–4.5. It is the lowest efficiency contour the maker draws (50%), not a measured choke line.

Shaft-speed lines on the map run from 48k to 126k rpm.

Engines it suits

We ran every engine preset in the turbo matcher at three boost levels and ranked all 20 maps for each. These are the engines where this compressor came out in the top three and the whole operating line stayed on the map, with no surge or choke. Modelled estimate

15 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
Predator 5.2 SC (GT500) · Ford3 of 204,000 rpm30%2.20

22 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
Predator 5.2 SC (GT500) · Ford2 of 204,000 rpm13%2.69
Coyote Gen 4 · Ford3 of 204,000 rpm23%2.69

30 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
Coyote Gen 4 · Ford1 of 204,000 rpm12%3.25
4.6 / 5.4 4V (Cobra, GT500, Boss 260/290) · Ford1 of 204,000 rpm9%3.25
Coyote Gen 3 · Ford2 of 204,000 rpm13%3.25
5.7 Hemi (Eagle, VVT 2009+) · Chrysler3 of 203,500 rpm33%3.25
L76 / L77 (6.0 Gen IV) · GM3 of 203,500 rpm37%3.25
Coyote Gen 1 · Ford3 of 204,000 rpm15%3.25
Coyote Gen 2 · Ford3 of 204,000 rpm15%3.25
LS1 · GM3 of 204,000 rpm30%3.25

Assumptions (the matcher's defaults): stock torque-curve VE shape scaled to 92% peak, full boost from 3,500 rpm to redline, 120 °F charge after the intercooler, 77 °F ambient at sea level, 1.5 psi charge-side and 0.5 psi inlet losses, gasoline. A compressor map says nothing about spool or transient response; the turbine housing decides much of that. The interactive turbo matcher opens once map review is complete.

Compare

Related

How these numbers are made

Method
manual reading from the maker's published map image at 928x689 px (left contour branches read from pixel row scans and assigned by counting from the surge line; right/lower branches traced with a pixel line-follower and checked against column scans and zoomed grid-overlaid renders; contours closed along the surge line, the 600 m/s top line, the right-hand boundary, the choke line through the speed-line ends and the 230 m/s bottom line; resampled to 22 points)
Accuracy
0.62-0.74 islands: +/-0.6 lb/min, +/-0.03 PR on traced branches; the lower (fan) branches of 0.62-0.66 between PR 1.3 and 1.8 are closely bunched and partly interpolated (+/-1.5 lb/min). 0.50-0.60 islands are mostly bounded by the map edge (surge, top, right boundary, choke, bottom speed line), so they are close to the whole map outline; their left branches near the surge are +/-0.5 lb/min. Map image is low resolution (~0.13 lb/min and ~0.007 PR per pixel).
Flow correction
298.2 K, 100.00 kPa. The map image states only 'Compressor Flow (lb/min)' and 'Pressure Ratio'; no correction reference or PR basis is printed. Value used is BorgWarner's own documented convention from the BorgWarner MatchBot sizing tool that publishes this map (bot.js corrects compressor flow as m*sqrt((T+460)/537 R)/(P_kPa/100): 537 R ~ 298 K, 100 kPa). Speed lines are labelled in tip speed (m/s); the map ties 561 m/s to 117,533 rpm, and the 230 m/s and 600 m/s lines are converted to rpm with that ratio.
Pressure-ratio basis
Not stated on the maker's map

Every figure on this page is a modelled estimate derived from that digitisation. It is not a flow-bench or dyno result and makes no power claim.

Sources

BorgWarner and model names are trademarks of their owners and identify the part only. No affiliation or endorsement is implied.