Garrett G40-1150 compressor map

G-SeriesG40 frame71 mm inducer88 mm exducerModelled estimate

Map data from Garrett Motion, retrieved 2026-10-25.

The Garrett G40-1150 compressor peaks at 78% efficiency around 69 lb/min and a pressure ratio of 2.6. Its map reaches a pressure ratio of about 4.4, and at a pressure ratio of 2 it flows from about 23 lb/min (surge) to 94 lb/min (choke side).

Peak efficiency
78%
island 52–85 lb/min, PR 1.9–3.3
Surge line
12–73
lb/min, from PR 1.4 to 4.4
Choke side, max flow
107
lb/min (0.810 kg/s)
Pressure-ratio reach
4.40
about 50 psi boost at sea level, before losses
Map width at PR 2
4.1×
choke flow ÷ surge flow
Outlet temp at peak island
292 °F
from 77 °F inlet, PR 2.6, 78% efficiency

Flow range

0306090120

Light band: usable flow at a pressure ratio of 2 (surge to choke side). Solid band: the 78% island. Scale 0–120 lb/min. We show figures derived from the map, not the map itself. See the maker's compressor map for the full islands and speed lines.

Surge and choke

Surge is the left-hand limit: too little flow for the pressure ratio, so air reverses through the wheel. On this map the surge line runs from about 12.3 lb/min (0.093 kg/s) at a pressure ratio of 1.4 to 72.9 lb/min (0.551 kg/s) at 4.4. Keep the full-load operating line to the right of it, with margin for transients.

Choke is the right-hand limit, where efficiency falls away and the wheel can't pass more air. The digitised choke side spans 37.3 lb/min (0.282 kg/s) to 107.2 lb/min (0.810 kg/s) across pressure ratios 1.1–4.4. It is the lowest efficiency contour the maker draws (65%), not a measured choke line.

Shaft-speed lines on the map run from 50k to 125k rpm.

Engines it suits

We ran every engine preset in the turbo matcher at three boost levels and ranked all 20 maps for each. These are the engines where this compressor came out in the top three and the whole operating line stayed on the map, with no surge or choke. Modelled estimate

15 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
Voodoo 5.2 (flat-plane, GT350) · Ford1 of 204,500 rpm16%2.20
7.3 Godzilla · Ford2 of 203,500 rpm69%2.20
LS7 · GM2 of 203,500 rpm56%2.20
M156 6.2 · Mercedes2 of 204,000 rpm36%2.20
6.1 / 6.4 392 Hemi · Chrysler2 of 203,500 rpm47%2.20
LS9 (supercharged) · GM2 of 203,500 rpm35%2.20
6.2 Hellcat / Redeye (SC) · Chrysler2 of 203,500 rpm31%2.20
LT4 (supercharged) · GM3 of 203,500 rpm38%2.20

22 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
Voodoo 5.2 (flat-plane, GT350) · Ford1 of 204,500 rpm8%2.69
7.3 Godzilla · Ford2 of 203,500 rpm59%2.69
LS3 / L99 · GM2 of 203,500 rpm30%2.69
LT1 (Gen V) · GM2 of 203,500 rpm30%2.69
LT4 (supercharged) · GM2 of 203,500 rpm30%2.69
LSA (supercharged) · GM2 of 203,500 rpm26%2.69
M156 6.2 · Mercedes2 of 204,000 rpm28%2.69
LS9 (supercharged) · GM2 of 203,500 rpm26%2.69

30 psi, single turbo

EngineRankEfficient fromLowest surge marginPeak PR
L76 / L77 (6.0 Gen IV) · GM2 of 203,500 rpm20%3.25
LS1 · GM2 of 204,000 rpm14%3.25
LS6 · GM2 of 204,000 rpm12%3.25
LS2 · GM2 of 203,500 rpm20%3.25
5.7 Hemi (Eagle, VVT 2009+) · Chrysler2 of 204,000 rpm17%3.25
Coyote Gen 1 · Ford2 of 204,000 rpm1%3.25
Coyote Gen 2 · Ford2 of 204,000 rpm1%3.25
L84 5.3 / L87 6.2 (Gen V with DFM) · GM2 of 204,000 rpm8%3.25

Assumptions (the matcher's defaults): stock torque-curve VE shape scaled to 92% peak, full boost from 3,500 rpm to redline, 120 °F charge after the intercooler, 77 °F ambient at sea level, 1.5 psi charge-side and 0.5 psi inlet losses, gasoline. A compressor map says nothing about spool or transient response; the turbine housing decides much of that. The interactive turbo matcher opens once map review is complete.

Turbine housings

The maker's turbine flow chart for this frame lists 8 housings. Highest corrected gas flow digitised for each:

HousingMax corrected flow (lb/min)At expansion ratio
84 trim V-band 1.19 A/R42.52.50
84 trim T4 1.19 A/R41.52.50
84 trim V-band 1.06 A/R40.22.50
84 trim T4 1.06 A/R39.42.50
84 trim V-band 0.95 A/R37.72.75
84 trim T4 0.95 A/R37.32.75
84 trim V-band 0.85 A/R35.33.00
84 trim T4 0.85 A/R35.33.00

Expansion ratio and flow as labelled on the maker's chart. See A/R ratio for how housing size trades spool against top-end flow.

Maker's published spec

Family
G-Series
Bearing
dual ceramic ball bearing, steel cages
Compressor wheel
71 mm inducer, 88 mm exducer
Turbine housing A/R
0.85, 0.95, 1.06, 1.19
Maker's engine size range
2.0L-6.0L

Compare

Related

How these numbers are made

Method
manual reading from the maker's published map image at 1714x2048 px, assisted by row-wise dark-pixel crossing scans on a calibrated pixel grid (axis ticks located to +/-1 px)
Accuracy
about +/-1.5% of axis span on surge, left/lower island branches and speed lines; about +/-3% of axis span on the near-choke right-hand island sides (drawn dashed by Garrett and overlapped by labels)
Flow correction
302.8 K, 96.18 kPa. Not printed on this map image (Garrett's current web maps carry no correction footnote and none was found on garrettmotion.com). Values are Garrett's long-standing convention printed on its legacy GT-series compressor maps: 545 degR (85 degF) and 13.95 psia. Treat as assumed, not maker-stated for this map. One further, unlabelled contour outside the 65% island (its lower branch forms the lower-right map boundary) is omitted because its value is not printed.
Pressure-ratio basis
Not stated on the maker's map

Every figure on this page is a modelled estimate derived from that digitisation. It is not a flow-bench or dyno result and makes no power claim.

Sources

Garrett and model names are trademarks of their owners and identify the part only. No affiliation or endorsement is implied.